Page 1: ...mp is a SAFE psi for the application s piping and fixtures If required a pressure reducing valve can be installed in line after the booster system to reduce water pressure to a safe level A pressure relief valve piped to a suitable drain is recommended for overall system protection Never install or service the pump or system without relieving the internal pressure 2 WARNING HAZARDOUS VOLTAGE Volta...

Page 2: ...ngs on the inlet side of pump and discharge side of pump controller for ease of disconnecting booster system for service or to protect from freezing ELECTRICAL CONNECTIONS Wiring to this booster system must be installed and maintained in accordance with both the National Electrical Code and state local codes Make sure motor voltage rating matches available power supply See the motor nameplate Dual...

Page 3: ...tecting leakage in the service piping greater than 0 21 GPM the value of the minimum flow below which the flow switch stops the booster pump MASCONTROL will protect the booster pump from damage if the city supply piping to the booster pump inlet is dry or blocked MASCONTROL will detect irregular city water supply conditions and shut off the booster pump The red Failure light will be on After the p...

Page 4: ...unting MASCONTROL pump controller see Figure 1 The MASCONTROL may be mounted directly on the booster pump s outlet MASCONTROL must be mounted on a vertical column with the electronic box level and the flow direction arrows pointing upward Use only Teflon tape for threaded connections Do not install any tap between the pump and the MASCONTROL Detailed system installation diagram see Figure 2 Relief...

Page 5: ... wiring diagrams Replace MASCONTROL s electronic box cover using the six screws upon completion of wiring the system If cover is not securely fastened RESTART button will not operate Figure 3A 115VAC Single Phase Wiring Diagram Figure 3B 230VAC Single Phase Wiring Diagram 8 Position Terminal Block MASCONTROL Model 8 Position Terminal Block MASCONTROL Model Figure 4 115VAC or 230VAC Single Phase Wi...

Page 6: ...lled and ready to operate automatically Using the RESTART Button If water does not enter the pump and MASCONTROL the red FAILURE light will illuminate and the MASCONTROL will shut off the pump within 20 30 seconds This is the run dry protection feature preventing damage to the pumps internal components See Figure 9 After the water supply problem is corrected is a check valve installed backwards di...

Page 7: ...astened to the proper terminals Also recheck voltage for correct application 115V or 230V Press the restart button If all lights remain on and the pump still does not operate the electronic box has failed and should be replaced POWER ON PUMP ON and FAILURE lights are all on Tap closed pump on Fig 14 The pump is operating and all taps are closed the electronic box has failed and must be replaced PO...