background image

 

8

 
SECTION 7 – TROUBLE SHOOTING 

  

 
 

 

 

 

 

ERROR

 

CAUSE

 

SOLUTION

 

1. No welding power 

  

Main power switch on, ready for 
operation lamp does not light up 

Power connection interrupted

 

 
 

Check power connection and main 
voltage 
 

2. No welding power 

 

 

Power main switch on. Ready for 
operation lamp lights up (yellow) 

Welding cable connection interrupted  
 
Bad or no grounding 

Check connectors 
 
Connect to work piece. Attach contact 
clamps directly to the work piece 

3. No welding power  

Main power switch on ready for 
operation lamp is constantly lit up 
(orange) 
 

Interruption due to power error 

Press the reset button or turn device 
on and off 
If still error, take device to be serviced 

4. Hard to ignite 
 

 

Bad grounding contact 
 
Dirty electrode 
 
Burned down electrode tip 

Connect to work piece 
 
Re-sharpen electrode 
 
Re-sharpen electrode 

5. Power fuse and/or automatic 
safety blows 

 

Not enough power protection 
Wrong automat 
 
Netzsicherung löst im Leerlauf aus 

Install proper power protection 
 
 
Send device to be serviced 

6. Welding unsatisfactory  

Wrong safety gas, no inert gas 
 

Use inert  gas (Argon 4.6) 
 
 

7. Oxidation and soot development 

Gas pressure too high 

Reduce flow to ca. 3 to 4 l/min 
 

7 Heavy oxidation development on 
the welding spot 
 

Wrong safety gas, no inert gas 
 

Use inert gas (Argon 4.6) 

8. Tungsten in basic material 
 

Too much electrode pressure on the 
work piece 

Lightly touch work piece so that it 
barely ignites enough 

9. Tungsten electrode adheres to 
work piece 

Too much electrode pressure on the 
work piece 

Lightly touch work piece so that it 
barely ignites enough 

10. Tungsten electrode melts off 
 

Tip sharpened too much 

Sharpen to the recommended angle 
(ca. 25°) 

11. Static discharge over the device 
surface 
 

Special location   

Use special floor mat for the work area

12. Work piece adheres to the 
welding table 
 

Bad connection to welding table 

Use clamps or pliers 

 

 
WARNING! Authorized personnel may only open the device!

 

 

 
 

Text and images correspond to the technical version during print of this manual. We reserve the right to change components. 

 
 
 
 
 
 
 
 

 
 
 
 

Summary of Contents for optiwelder T1

Page 1: ...Operating Instructions Precision Welding Device optiwelder T1 and PUK Optic Device Lampert Werktechnik GmbH 230V...

Page 2: ...rer will not be liable for any damages which result from improper usage or treatment Please read the sections General Safety Rules and Personal Body Protection carefully before you start up the device...

Page 3: ...tanium and various NE metals and nickel alloys such as brass German silver monel or EVO Also suitable for precious metals and precious metals alloys Not approved for welding dentures Dentistry Any usa...

Page 4: ...The welding device is set by the manufacturer at 230V this means the device may due to the tolerance of 15 also be operated on a 220V power Devices that operate on a different power than 230V will be...

Page 5: ...ECTOR JACK FOR HAND PIECE 5 JACKS 6 For connecting the contact elements such as welding table clamps and holding pliers 4 3 DESRIPTION OF THE OPERATIONS ELEMENTS BACK SIDE Illus 2 FUSEBOX 7 Fuse box w...

Page 6: ...and set the gas flow to ca 3 6 liter per minute m a x i m u m operating pressure 10 bar Insert the power plug Switch the mains power switch 8 to ON the device will perform an automatic test The yellow...

Page 7: ...ng addition For deeply located welding spots the electrode should be longer It may be helpful to use wire as a welding addition to close holes or as reinforcement Only use welding wires as a welding a...

Page 8: ...RGON 99 9 ARGON 4 6 Maximum gas pressure 10 bar Inert class I Insulation class B Weight 5 20 kg 6 2 Identification Plate Symbol explanations Amperage Voltage Protection Method Hertz Alternating Curren...

Page 9: ...t im Leerlauf aus Install proper power protection Send device to be serviced 6 Welding unsatisfactory Wrong safety gas no inert gas Use inert gas Argon 4 6 7 Oxidation and soot development Gas pressur...

Page 10: ...EWG According to EMV electro magnetic compatibility guidelines 89 336 EWG The Manufacturer Lampert Werktechnik GmbH Julius Echter Str 4 97440 Werneck Germany declares that the product optiwelder T1 Sp...

Page 11: ...10...

Page 12: ...e for any damages which result from improper usage or treatment Please read the sections General Safety Rules and Personal Body Protection carefully before you start up the device Note The devices man...

Page 13: ...SAFETY RULES A professional may only open the device Remove the power plug and make sure the device is not under live power Always contact your professional if you are uncertain Before replacing the e...

Page 14: ...ON The view protection filter 2 must switch from dark to bright shortly after turning on the device for a test Perform this test every time before you begin working with this device to make sure it is...

Page 15: ...ation unit welding shield only to be operated with the Opti Welder Precision welding device Use only in dry environments Operating temperature 5 C to 40 C Mains Voltage 15 230 V 50 60 Hz Illumination...

Reviews: