background image

 

7

SECTION 6 – TECHNICAL DATA 

 
6-1. TECHNICAL DATA 

 

  Device is suitable for spot and precision welding in dry environments 

  Main Voltage ~230 V / 50-60 Hz +/-15%  

  Mains fuse T 2,5 A 

  Power input 500 VA 

  Operating voltage: 20 – 38 V 

  No l- load voltage 38 V 

  max. charging time 3 sec 

  Inert gas: min. ARGON 99,9% (ARGON 4.6) 

  Maximum gas pressure 10 bar 

  Inert class I 

 Insulation 

class 

  Weight 5,20 kg 

 
 

 

 

6-2. Identification Plate 

 
 

Symbol explanations: 

 

 

Amperage 

 

 
 

Voltage 

 

Protection 

Method 

 

 

 

Hertz 

 

 
 

Alternating 

Current 

(AC) 

 

Tungsten-Inert 

Gas-Welding 

 

 

 
 

Direct Current 

 

1 ~ 50-60Hz 

 

Power plug 

single phase / 

Alternating 

Current / 50-60Hz

 

 

Read the manual

 

 

Idling Voltage 

 

 

Mains Voltage 

 

Ground 

 

Nominal Voltage 

 

 

 

Nominal welding 

current 

 

Single phase 

transformer 

 

Amperage input 

 

 

 

Rated Amperage 

input 

 

 

 

Duty cycle 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for optiwelder T1

Page 1: ...Operating Instructions Precision Welding Device optiwelder T1 and PUK Optic Device Lampert Werktechnik GmbH 230V...

Page 2: ...rer will not be liable for any damages which result from improper usage or treatment Please read the sections General Safety Rules and Personal Body Protection carefully before you start up the device...

Page 3: ...tanium and various NE metals and nickel alloys such as brass German silver monel or EVO Also suitable for precious metals and precious metals alloys Not approved for welding dentures Dentistry Any usa...

Page 4: ...The welding device is set by the manufacturer at 230V this means the device may due to the tolerance of 15 also be operated on a 220V power Devices that operate on a different power than 230V will be...

Page 5: ...ECTOR JACK FOR HAND PIECE 5 JACKS 6 For connecting the contact elements such as welding table clamps and holding pliers 4 3 DESRIPTION OF THE OPERATIONS ELEMENTS BACK SIDE Illus 2 FUSEBOX 7 Fuse box w...

Page 6: ...and set the gas flow to ca 3 6 liter per minute m a x i m u m operating pressure 10 bar Insert the power plug Switch the mains power switch 8 to ON the device will perform an automatic test The yellow...

Page 7: ...ng addition For deeply located welding spots the electrode should be longer It may be helpful to use wire as a welding addition to close holes or as reinforcement Only use welding wires as a welding a...

Page 8: ...RGON 99 9 ARGON 4 6 Maximum gas pressure 10 bar Inert class I Insulation class B Weight 5 20 kg 6 2 Identification Plate Symbol explanations Amperage Voltage Protection Method Hertz Alternating Curren...

Page 9: ...t im Leerlauf aus Install proper power protection Send device to be serviced 6 Welding unsatisfactory Wrong safety gas no inert gas Use inert gas Argon 4 6 7 Oxidation and soot development Gas pressur...

Page 10: ...EWG According to EMV electro magnetic compatibility guidelines 89 336 EWG The Manufacturer Lampert Werktechnik GmbH Julius Echter Str 4 97440 Werneck Germany declares that the product optiwelder T1 Sp...

Page 11: ...10...

Page 12: ...e for any damages which result from improper usage or treatment Please read the sections General Safety Rules and Personal Body Protection carefully before you start up the device Note The devices man...

Page 13: ...SAFETY RULES A professional may only open the device Remove the power plug and make sure the device is not under live power Always contact your professional if you are uncertain Before replacing the e...

Page 14: ...ON The view protection filter 2 must switch from dark to bright shortly after turning on the device for a test Perform this test every time before you begin working with this device to make sure it is...

Page 15: ...ation unit welding shield only to be operated with the Opti Welder Precision welding device Use only in dry environments Operating temperature 5 C to 40 C Mains Voltage 15 230 V 50 60 Hz Illumination...

Reviews: