7
SECTION 6 – TECHNICAL DATA
6-1. TECHNICAL DATA
•
Device is suitable for spot and precision welding in dry environments
•
Main Voltage ~230 V / 50-60 Hz +/-15%
•
Mains fuse T 2,5 A
•
Power input 500 VA
•
Operating voltage: 20 – 38 V
•
No l- load voltage 38 V
•
max. charging time 3 sec
•
Inert gas: min. ARGON 99,9% (ARGON 4.6)
•
Maximum gas pressure 10 bar
•
Inert class I
•
Insulation
class
B
•
Weight 5,20 kg
6-2. Identification Plate
Symbol explanations:
Amperage
Voltage
Protection
Method
Hertz
Alternating
Current
(AC)
Tungsten-Inert
Gas-Welding
Direct Current
1 ~ 50-60Hz
Power plug
single phase /
Alternating
Current / 50-60Hz
Read the manual
Idling Voltage
Mains Voltage
Ground
Nominal Voltage
Nominal welding
current
Single phase
transformer
Amperage input
Rated Amperage
input
Duty cycle
Summary of Contents for optiwelder T1