OPERATING INSTRUCTIONS 

MEZZO 

Welding microscope with LED-Lighting 

For using with PUK 3s welding devices

 

 

Dear Customer 

This manual will explain the operating principles and correct maintenance of your “mezzo”. 

The “mezzo” is a microscope that has been specially modified to suit the here described 

applications and uses. Lamperts stereo microscopes are precision instruments that 

undergo intensive testing prior to delivery, to ensure that they reach you in perfect 

condition. The design allows simple handling, needs only a minimum of maintenance and 

at the same time offers outstanding functionality. 

Please read this manual carefully and clearly observe the guidelines it describes; this way 

malfunctions and operating errors can be avoided. Adhering to the guidelines will promote 

the working life of the machine and assure that it remains in constant operational 

readiness during this time; it will also ensure your personal safety. 

This device may only be operated by qualified personnel, and then only for its 

designated use and in accordance with the guidelines here within. The 

manufacturer accepts no responsibility, and is in no way liable for damage caused 

by improper use or operation of the machine. Before first using your “mezzo”, 

please be sure to carefully read the manual sections “General Safety Requirements” 

and “Personal safety”. 

Please retain these instructions for future reference. 

A note on conformity marks 

The equipment made by “Lampert Werktechnik GmbH”, fulfils the conformity requirements 

of CE certification and is manufactured according to VDE guidelines. 

The LCD-shutters used for this microscope have been tested and authorised, and carry 

the DIN-CERTCO certification from the DIN authority for eye protection. 

When overhauling or reconditioning our devices, we strongly advise only to use original 

parts. Our customer service team is at your disposal, and will gladly assist in any way they 

can. 

The device may only be opened, or alterations carried out, by authorised customer 

service technicians. Non-compliance will result in all warrantees and liability claims 

becoming void. 

LAMPERT WERKTECHNIK GmbH 

February 2010 

 

Summary of Contents for MEZZO

Page 1: ...y qualified personnel and then only for its designated use and in accordance with the guidelines here within The manufacturer accepts no responsibility and is in no way liable for damage caused by imp...

Page 2: ...5 2 SETTING THE VIEWING DISTANCE 7 5 3 FOCUSSING 7 5 4 DIOPTRE SETTINGS 8 6 CARE AND MAINTENENCE 6 1 MAINTENANCE OF THE OPTICAL COMPONENTS 8 6 2 MAINTENANCE OF THE ELECTRICAL COMPONENTS 9 7 TROUBLE S...

Page 3: ...Precision Welding Device The MEZZO may only be used if set up according to the instructions Any usage other than herein specified is prohibited Operation in outdoor areas is prohibited Use in dry room...

Page 4: ...e device and secure it against unauthorised use It is clear that a hazardous conditions are present when the device shows visible damage or or when functional errors occur if it no longer functions pr...

Page 5: ...of the stereo microscope very carefully The stereo microscope s individual parts and elements should not be assembled too forcefully Mount the bearing rod 11 to the base plate 13 with the attachment...

Page 6: ...6 4 2 DESCRIPTION OF THE OPERATING ELEMENTS fig 1...

Page 7: ...rt in such a way that a workpiece can easily by hand be lead to the tip of a mounted tool holder Both hands or heels of the hand should be able to easily bear on the base plate Switch on the main ligh...

Page 8: ...ENCE The mezzo needs under ordinary working conditions only minimal care and maintenance Remembering a couple of points is crucial though to ensure proper functioning and a long life for your welding...

Page 9: ...supporting arm of the hand piece Remember that the module should fit flush with the underside of the supporting arm 7 TROUBLE SHOOTING PROBLEM CAUSE SOLUTION 7 1 PROBLEMS WITH ELECTRICAL COMPONENTS A...

Page 10: ...d on to the tripod rod 11 of the stereomicroscope with the other hand hold on to the base plate 13 Keep the stereomicroscope always upright 8 TECHNICAL DATA 8 1 TECHNICAL DATA MICROSCOPE Optical view...

Page 11: ...rotection system MEZZO conforms to the conditions set forth in the below named guidelines including any changes made up to the time of declaration Relevant EEC guidelines According to low voltage guid...

Reviews: