Lampert MEZZO Operating Instructions Manual Download Page 10

 

10 

  7-3  PROBLEMS WITH MECHANICAL COMPONENTS 

 

F  Focusing does not remain 

 

Focusing does not remain 
 

Focusing does not remain 
 

 

7-4  REPAIR 

 

 

If the stereomicroscope must be repaired or revised by technical personnel, we 
recommend, to send it back in its original packaging to the dealer. Attach a description of 
the problem or the desired revision. 

 

 

WARNING! Authorized personnel may only open the device! 

 

7-5  TRANSPORT THE MICROSCOPE 

 

 

If possible avoid to move the stereomicroscope.  

 

 

Carry the stereomicroscope with both hands. With one hand hold on to the tripod rod (11) 
of the stereomicroscope, with the other hand hold on to  the base plate (13). 

 

 

Keep the stereomicroscope always upright. 

 

 

 

 

  

TECHNICAL DATA 

 

  

8-1  TECHNICAL DATA MICROSCOPE 

 

  

  

Optical view protection and illumination unit (welding shield) only 
to be operated with the PUK 3-Precision welding device 

 

  

 

 

Use only in dry environments 

 

  

 

 

Operating temperature 

+5°C bis +40°C 

  

 

 

Bulb  “LED-module” 

2,5W / 800mA 

  

 

 

Protection class 

III 

  

 

 

Insulation class 

  

 

 

Type of protection 

IP 20 

 

 

 

Weight 

3,7 Kg 

  

8-2

 

OPTICAL DATA MICROSCOPE 

 

  

 

 

Lens 

1,0 

  

 

 

Eyepiece 

10x 

  

 

 

Work distance 

140 mm 

 

 

 

Enlargement factor 

10x 

 

 

 

Field of view 

20 mm 

 

8-3

 

TECHNICAL DATA LCD-SHUTTER 

 

 

 

 

Brightness level 

DIN 3 

 

 

 

Darkness level 

DIN 11 

 

 

 

Circuit time 

<50ms 

 

 

 

UV Protection 

>UV 15 

 

 

 

IR Protection  

>IR 14 

 

 

Summary of Contents for MEZZO

Page 1: ...y qualified personnel and then only for its designated use and in accordance with the guidelines here within The manufacturer accepts no responsibility and is in no way liable for damage caused by imp...

Page 2: ...5 2 SETTING THE VIEWING DISTANCE 7 5 3 FOCUSSING 7 5 4 DIOPTRE SETTINGS 8 6 CARE AND MAINTENENCE 6 1 MAINTENANCE OF THE OPTICAL COMPONENTS 8 6 2 MAINTENANCE OF THE ELECTRICAL COMPONENTS 9 7 TROUBLE S...

Page 3: ...Precision Welding Device The MEZZO may only be used if set up according to the instructions Any usage other than herein specified is prohibited Operation in outdoor areas is prohibited Use in dry room...

Page 4: ...e device and secure it against unauthorised use It is clear that a hazardous conditions are present when the device shows visible damage or or when functional errors occur if it no longer functions pr...

Page 5: ...of the stereo microscope very carefully The stereo microscope s individual parts and elements should not be assembled too forcefully Mount the bearing rod 11 to the base plate 13 with the attachment...

Page 6: ...6 4 2 DESCRIPTION OF THE OPERATING ELEMENTS fig 1...

Page 7: ...rt in such a way that a workpiece can easily by hand be lead to the tip of a mounted tool holder Both hands or heels of the hand should be able to easily bear on the base plate Switch on the main ligh...

Page 8: ...ENCE The mezzo needs under ordinary working conditions only minimal care and maintenance Remembering a couple of points is crucial though to ensure proper functioning and a long life for your welding...

Page 9: ...supporting arm of the hand piece Remember that the module should fit flush with the underside of the supporting arm 7 TROUBLE SHOOTING PROBLEM CAUSE SOLUTION 7 1 PROBLEMS WITH ELECTRICAL COMPONENTS A...

Page 10: ...d on to the tripod rod 11 of the stereomicroscope with the other hand hold on to the base plate 13 Keep the stereomicroscope always upright 8 TECHNICAL DATA 8 1 TECHNICAL DATA MICROSCOPE Optical view...

Page 11: ...rotection system MEZZO conforms to the conditions set forth in the below named guidelines including any changes made up to the time of declaration Relevant EEC guidelines According to low voltage guid...

Reviews: