Lampert MEZZO Operating Instructions Manual Download Page 5

 

 

INSTALLATION 

 

4-1  UNPACKING 

 

  

All components of the stereo microscope are carefully packed, ensuring delivery in an 
immaculate condition. We recommend to keep the packaging material, as it is used for 
sending in the microscope or storing it for a longer period of time or transporting it to a 
technical service team.  

 

  

The MEZZO packaging contains the following components: 

 

  

Microscope head with mount and LCD glare protection filter (4.2 Fig.1 - 10) 

 

  

Two eyepieces with eyepiece covers (4.2 Fig. 2 - 1) 

 

 

Supporting arm (for holding the welding hand-piece), with integrated LED light (4.2 
Fig.12) 

 

 

Bearing rod (4.2 Fig.1 -11) 

 

 

Base plate, for attaching the bearing rod (4.2 Fig.1 -13) 

 

 

Protective cover 

 

 

Tools for adjusting the focussing levels 

 

 

Remove and handle all microscope components with great care.  

 

 

Avoid touching the lenses and optical elements. Also avoid contact with dust, water and 
other polluting substances, as they soil or damage the lense surfaces and influence the 
quality of the view.  

 

 

ASSEMBLY AND START-UP 

 

 

Please perform all work stages involved with the assembly of the stereo 
microscope very carefully. The stereo microscope’s individual parts and elements 
should not be assembled too forcefully.  

 

 

Mount the bearing rod (11) to the base plate (13) with the attachment screw and place it 
upright onto an even, safe and clean surface  

 

 

Slide the supporting arm (12) over the bearing rod (11) and secure it slightly above the 
middle of the rod, tightening hand tight. 

 

 

Slide the microscope head (8) and its mount with retaining screw (9) over the bearing rod 
(11), and secure it at about 5cm above the supporting arm for the hand-piece (12). 

 

 

Insert eyepieces (1) and eyepiece covers and secure with locking screw (4) 

 

 

Connect the control line (15) to the eye protection filter (shutter) (6) with the welding 
device (note welding device instructions!)  

 

 

Connect the LED light with the PUK 3s . 
Insert the mains cable (16) into the connection socket marked “LED-Lamp 800 mA”, on 
the back of the welding device. 

 

 

Note! 

 

 

Always test that the eye protection system (shutter) is in correct functioning order 
before you start welding. 

 

 

Through a press on the output power regulator of the welding device "PUK 3s",  
you switch the eye protection filter from bright to dark. 

 

 

If the eye protection filter (Shutter) does not switch from bright to dark, it must 
immediately be replaced. 

 

 

 

Summary of Contents for MEZZO

Page 1: ...y qualified personnel and then only for its designated use and in accordance with the guidelines here within The manufacturer accepts no responsibility and is in no way liable for damage caused by imp...

Page 2: ...5 2 SETTING THE VIEWING DISTANCE 7 5 3 FOCUSSING 7 5 4 DIOPTRE SETTINGS 8 6 CARE AND MAINTENENCE 6 1 MAINTENANCE OF THE OPTICAL COMPONENTS 8 6 2 MAINTENANCE OF THE ELECTRICAL COMPONENTS 9 7 TROUBLE S...

Page 3: ...Precision Welding Device The MEZZO may only be used if set up according to the instructions Any usage other than herein specified is prohibited Operation in outdoor areas is prohibited Use in dry room...

Page 4: ...e device and secure it against unauthorised use It is clear that a hazardous conditions are present when the device shows visible damage or or when functional errors occur if it no longer functions pr...

Page 5: ...of the stereo microscope very carefully The stereo microscope s individual parts and elements should not be assembled too forcefully Mount the bearing rod 11 to the base plate 13 with the attachment...

Page 6: ...6 4 2 DESCRIPTION OF THE OPERATING ELEMENTS fig 1...

Page 7: ...rt in such a way that a workpiece can easily by hand be lead to the tip of a mounted tool holder Both hands or heels of the hand should be able to easily bear on the base plate Switch on the main ligh...

Page 8: ...ENCE The mezzo needs under ordinary working conditions only minimal care and maintenance Remembering a couple of points is crucial though to ensure proper functioning and a long life for your welding...

Page 9: ...supporting arm of the hand piece Remember that the module should fit flush with the underside of the supporting arm 7 TROUBLE SHOOTING PROBLEM CAUSE SOLUTION 7 1 PROBLEMS WITH ELECTRICAL COMPONENTS A...

Page 10: ...d on to the tripod rod 11 of the stereomicroscope with the other hand hold on to the base plate 13 Keep the stereomicroscope always upright 8 TECHNICAL DATA 8 1 TECHNICAL DATA MICROSCOPE Optical view...

Page 11: ...rotection system MEZZO conforms to the conditions set forth in the below named guidelines including any changes made up to the time of declaration Relevant EEC guidelines According to low voltage guid...

Reviews: