GENERAL SAFETY INSTRUCTIONS - READ BEFORE USING 

 

3-1  GENERAL SAFETY RULES 

 

  

A professional may only open the device. Remove the power plug and make sure the 
device is not under live power. Always contact your professional if you are uncertain. 

 

  

Before exchanging the LED module, remove the power supply plug. Only use original 
replacement LED modules from Lampert. 

 

  

It is illegal for non-professional electricians to handle parts that are directly connected to 
the mains power supply, except in cases of pulling the mains plug and/or operating the 
main power switch. 

 

  

The device must be disconnected from the mains as soon as repair or service works is 
needed.  When leaving the place of work even for a short time, make sure that the 
electrical outlet is blocked clearly. 

 

  

If you believe that operating the device is not possible without creating hazardous 
conditions, then shut off the device and secure it against unauthorised use. 

 

  

It is clear that a hazardous conditions are present when: 

 

  

- the device shows visible damage,or 

 

  

- or when functional errors occur 

 

  

- if it no longer functions properly.   

 

 

 

 

 

 

 

3-2  PERSONAL BODY PROTECTION AND DANGERS 

 

  

EYE PROTECTION DURING WELDING 

 

  

Do not look into arc without protecting your eyes. Use only a welders’ face 
protection shield with protecting glass that conforms to regulation (minimum 
protection level 11). 

 

 

The arc releases not only light and heat causing blindness or burning but also emits UV 
rays. If insufficient protection is used, the UV beams can cause very painful conjunctivital 
inflammation only noticeable after several hours. 

 

 

Bystanders close to the arcs also should be made aware of possible dangerous 
conditions and should wear protective equipment. If necessary protective walls should be 
set up. 

 

 

EYE PROTECTION WHILST OPPERATING THE LED LAMP  

 

 

Do not look into the LED Lamp, or into the reflection of the LED light, without eye 
protection. Always use a welders’ protective glare shield with a minimum 
protection class of 3. 

 

 

 

 

 

 

 

 

Summary of Contents for MEZZO

Page 1: ...y qualified personnel and then only for its designated use and in accordance with the guidelines here within The manufacturer accepts no responsibility and is in no way liable for damage caused by imp...

Page 2: ...5 2 SETTING THE VIEWING DISTANCE 7 5 3 FOCUSSING 7 5 4 DIOPTRE SETTINGS 8 6 CARE AND MAINTENENCE 6 1 MAINTENANCE OF THE OPTICAL COMPONENTS 8 6 2 MAINTENANCE OF THE ELECTRICAL COMPONENTS 9 7 TROUBLE S...

Page 3: ...Precision Welding Device The MEZZO may only be used if set up according to the instructions Any usage other than herein specified is prohibited Operation in outdoor areas is prohibited Use in dry room...

Page 4: ...e device and secure it against unauthorised use It is clear that a hazardous conditions are present when the device shows visible damage or or when functional errors occur if it no longer functions pr...

Page 5: ...of the stereo microscope very carefully The stereo microscope s individual parts and elements should not be assembled too forcefully Mount the bearing rod 11 to the base plate 13 with the attachment...

Page 6: ...6 4 2 DESCRIPTION OF THE OPERATING ELEMENTS fig 1...

Page 7: ...rt in such a way that a workpiece can easily by hand be lead to the tip of a mounted tool holder Both hands or heels of the hand should be able to easily bear on the base plate Switch on the main ligh...

Page 8: ...ENCE The mezzo needs under ordinary working conditions only minimal care and maintenance Remembering a couple of points is crucial though to ensure proper functioning and a long life for your welding...

Page 9: ...supporting arm of the hand piece Remember that the module should fit flush with the underside of the supporting arm 7 TROUBLE SHOOTING PROBLEM CAUSE SOLUTION 7 1 PROBLEMS WITH ELECTRICAL COMPONENTS A...

Page 10: ...d on to the tripod rod 11 of the stereomicroscope with the other hand hold on to the base plate 13 Keep the stereomicroscope always upright 8 TECHNICAL DATA 8 1 TECHNICAL DATA MICROSCOPE Optical view...

Page 11: ...rotection system MEZZO conforms to the conditions set forth in the below named guidelines including any changes made up to the time of declaration Relevant EEC guidelines According to low voltage guid...

Reviews: