KYRA D 30 SI UNIT COND

45

A73022660

EN

Circulating pump

Faults must only be repaired by quali

fi

 ed specialist technicians, work on electrical 

connections must only be carried out by quali

fi

 ed specialist electricians.

Faults

Causes

Cures

Pump not 
working with 
power switched 
on

Faulty electrical fuse

Check fuses

No power to pump

Eliminate the power supply 
interruption

Noisy pump

Cavitation due to 
insuf

fi

 cient delivery 

pressure

Increase the system pressure 
within the permissible range
Check the head setting and set a 
lower head if necessary

The building 
does not get 
warm

Radiant panel thermal 
power too low

Increase the delivery value
Set the adjustment mode to 

Δ

p-c 

instead of 

Δ

p-v

Fault signals

•  The fault LED signals a fault.
•  The pump stops (depending on the fault), and makes cyclical attempts to restart

LED

Faults

Causes

Cures

Lights up red

Fault

Blocked rotor

Activate manual 
restart or contact 
Customer Service

Contact/winding

Faulty winding

Flashes red

Under/overvoltage Supply side 

voltage too low/
high

Check the mains 
voltage and 
conditions of use. 
Request Customer 
Service

Excessive module 
temperature

Too hot inside 
module

Short circuit

Motor current too 
high

Flashing red/green Turbine operation

The hydraulic 
system of the 
pumps is fed, but 
the pump has no 
mains voltage

Check the mains 
voltage, 

fl

 ow rate/

water pressure 
and also the 
ambient conditions

Dry running

Air in pump

Overload

The motor turns 
with dif

fi

 culty. 

Pump not running 
according to 
speci

fi

 cations 

(e.g. high module 
temperature). The 
speed is lower 
than in normal 
operation.x

Table. 3 - List of faults

Fault 
code

Fault

Possible cause

Cure

A01 

Bloqueo del que-
mador

Pump blocked

Replace

Faulty electric motor

Replace

Faulty oil valve

Replace

No fuel in tank, or water 
on bottom

Re

fi

 ll with fuel or 

suck the water

Oil line feed valves 
closed

Open

Dirty 

fi

 lters (line-pump-

nozzle)

Clean

Pump unprimed

Prime and 

fi

 nd the 

cause of unpriming

Ignition electrodes not 
properly adjusted, or dirty

Adjust or clean them

Nozzle clogged, dirty or 
deformed

Replace

Unsuitable head and 
shutter adjustments

Adjust

Faulty electrodes or 
earthed

Replace

Faulty ignition transfor-
mer

Replace

Faulty electrode wires or 
earthed

Replace

Electrode wires deformed 
by high temperature

Replace and protect

Faulty valve or transfor-
mer electrical connec-
tions

Check

Broken pump-motor joint Replace
Pump inlet connected to 
return pipe

Correct the connec-
tion

Faulty photoresistance

Replace

Dirty photoresistance

Clean the photore-
sistance

A02

Flame present sig-
nal with burner off

Photoresistance short 
circuit

Replace the photore-
sistance

Extraneous light strikes 
the photoresistance

Eliminate the light 
source

A03

Overtemperature 
protection activation

Heating sensor damaged

Check the correct 
positioning and ope-
ration of the heating 
sensor

No water circulation in 
the system

Check the circulating 
pump.

Air in the system

Vent the system

A04

Card parameter fault

Wrong card parameter 
setting

Check the card para-
meter and modify it if 
necessary

F07 

Preheater fault 
(the contact does 
not close in 120 
seconds)

Preheater failure 

Check the preheater

Wiring disconnected

Check the wiring

A09

Card parameter fault

Wrong card parameter 
setting

Check the card para-
meter and modify it if 
necessary

F10 

Delivery sensor 1 
fault

Sensor damaged

Check the wiring or 
replace the sensor

Wiring shorted
Wiring disconnected

F11

DHW sensor fault

Sensor damaged

Check the wiring or 
replace the sensor

Wiring shorted
Wiring disconnected

F12

Card parameter fault

Wrong card parameter 
setting

Check the card para-
meter and modify it if 
necessary

F14 

Delivery sensor 2 
fault

Sensor damaged

Check the wiring or 
replace the sensor

Wiring shorted
Wiring disconnected

F16

Card parameter fault

Wrong card parameter 
setting

Check the card para-
meter and modify it if 
necessary

F34 

Supply voltage 
under 170V.

Electric mains trouble 

Check the electrical 
system

Summary of Contents for KYRA D 30 SI UNIT COND

Page 1: ...1 204 63 61 4712 77 13 04 4742 52 20 81 3519 55 03 13 495 268 04 70 8152 59 64 93 8552 20 53 41 831 429 08 12 3843 20 46 81 383 227 86 73 3812 21 46 40 4862 44 53 42 3532 37 68 04 8412 22 31 16 342 20...

Page 2: ...40 3 5 Electrical connections 40 3 6 Connection to the flue 41 3 7 Condensate drain connection 41 4 SERVICE AND MAINTENANCE 41 4 1 Adjustments 41 4 2 Commissioning 43 4 3 Maintenance 44 4 4 Troublesho...

Page 3: ...mplified representation of the product In this representation there may be slight and insignificant differences with re spect to the product supplied 2 OPERATING INSTRUCTIONS 2 1 Introduction Dear Cus...

Page 4: ...C fig 10 DHW temperature adjustment Use the DHW buttons details 1 and 2 fig 1 to adjust the temperature from a min of 10 C to a max of 65 C fig 11 Room temperature adjustment with optional room therm...

Page 5: ...FORMED BY QUALIFIED PER SONNEL IN ACCORDANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL MANUAL THE PROVISIONS OF CURRENT LAW THE PRESCRIP TIONS OF NATIONAL AND LOCAL STANDARDS AND THE RULES OF...

Page 6: ...ATTENTION After venting the LED indicator shows the pump set values Set the adjustment mode Select the adjustment mode The LED selection of the adjustment mode and the corresponding characteristic cur...

Page 7: ...nd exclusively if their manufacturer provides a guarantee ensuring that the products are suitable for use and do not cause damage to the boiler exchanger or to other components and or materials of the...

Page 8: ...ore starting the unit Verify Periodically check the water in the trap fig 23 Condensate drain 4 SERVICE AND MAINTENANCE All adjustment conversion commissioning and maintenance operations described bel...

Page 9: ...press the Reset button to access it tS Transparent Parameters Menu The card is equipped with 27 transparent parameters also modifiable from Remote Control Service Menu Index Description Range Default...

Page 10: ...ccurred relevant to Ht H5 Fault code Time fault occurred relevant to Ht H6 Fault code Time fault occurred relevant to Ht H7 Fault code Time fault occurred relevant to Ht H8 Fault code Time fault occur...

Page 11: ...The gas and water systems must be airtight The water pressure in the cold water system must be approx 1 bar otherwise bringit to that value The circulating pump must not be blocked The expansion tank...

Page 12: ...p nozzle Clean Pump unprimed Prime and find the cause of unpriming Ignition electrodes not properly adjusted or dirty Adjust or clean them Nozzle clogged dirty or deformed Replace Unsuitable head and...

Page 13: ...temperature F40 Incorrect system water pressure Pressure too high Check the system Check the safety valve Check the expansion vessel A41 Sensor positioning Delivery sensor not inser ted in boiler shel...

Page 14: ...utomatic air vent 38 Flow switch 42 DHW temperature sensor optional 56 Expansion vessel 74 Charging key 191 Smoke temperature sensor 246 Pressure transducer 275 Key download heating circuit 278 Double...

Page 15: ...iency class according to directive 92 42 CE Max working pressure in heating bar 3 PMS Min working pressure in heating bar 0 8 Max heating temperature C 80 tm x Heating water content liters 49 Heating...

Page 16: ...emperature regime 1 97 5 Auxiliary electricity consumption At full load elmax kW 0 188 At part load elmin kW 0 075 In standby mode PSB kW 0 003 Other items Standby heat loss Pstby kW 0 100 Ignition bu...

Page 17: ...3 204 51 73 343 384 55 89 4932 77 34 06 3412 26 03 58 395 279 98 46 843 206 01 48 4012 72 03 81 4842 92 23 67 3842 65 04 62 8332 68 02 04 861 203 40 90 391 204 63 61 4712 77 13 04 4742 52 20 81 3519 5...

Reviews: