TAURA 24 MC W TOP
32
4.3 Technical data table
Powers
Pmax
Pmin
Heating Power (Net Heat Value - Hi)
kW
25,8
11,5
Available Thermal Power 80°C - 60°C
kW
23,5
9,7
Hot Water Heating Power
kW
23,5
9,7
Gas supply
Pmax
Pmin
Natural Gas main nozzles (G20)
mm
11x1.35
Natural Gas supply pressure (G20)
mbar
20,0
Pressure at Natural Gas burner (G20)
mbar
11,8
2,5
Natural Gas delivery (G20)
nm3/h
2,73
1,22
LPG main nozzles (G31)
mm
11x0.79
LPG supply pressure (G31)
mbar
37,0
Pressure at LPG burner (G31)
mbar
36,0
7,2
LPG delivery (G31)
kg/h
2,00
0,89
Heating
Maximum working temperature in heating
°C
90
Maximum working pressure in heating
bar
3
Minimum working pressure in heating
bar
0,8
Expansion tank capacity
litres
8
Expansion tank pre-filling pressure
bar
1
Boiler water content
litres
0.5
Energy Efficiency Marking (EEC 92/42)
**
Hot water
Maximum hot water production
∆
t 30°C
l/min
11,2
Maximum working pressure in hot water production
bar
10
Minimum working pressure in hot water production
bar
0,25
Hot water content
litres
0,3
Electrical power supply
Max electrical power absorbed
W
85
Power voltage/frequency
V/Hz
230/50
Electrical protection rating
IP
X4D
Boiler weight
kg
25
4.4 Diagrams
Pressure - power diagrams
Head available for the system
0
1
2
3
4
5
6
0
500
1.000
1.500
2.000
Q
[l/h]
H
[m H
2
O]
mbar
kW
G31
LPG
G20
Natural
gas