TAURA 24 MC W TOP
26
After determining the parameter to set, it is necessary to use the following conversion tables to see what value is
being set, depending on the blinking of the LEDs. OFF means LED switched off, ON means LED switched on and
ON BL means LED blinking.
Red
Green
Yellow
Gas type selection
OFF
OFF
OFF
Natural gas
ON BL
OFF
OFF
LPG
Red
Green
Yellow
Heading idle time
OFF
OFF
OFF
00-30 seconds
ON BL
OFF
OFF
31-62 seconds
OFF
OFF
ON BL
63-94 seconds
ON BL
OFF
ON BL
95-126 seconds
OFF
ON BL
OFF
127-158 seconds
ON BL
ON BL
OFF
159-190 seconds
OFF
ON BL
ON BL
191-222 seconds
ON BL
ON BL
ON BL
223-255 seconds
Red
Green
Yellow
Pump post-circulation
OFF
OFF
OFF
0-2 minutes
ON BL
OFF
OFF
3-4 minutes
OFF
OFF
ON BL
5-7 minutes
ON BL
OFF
ON BL
8-9 minutes
OFF
ON BL
OFF
10-12 minutes
ON BL
ON BL
OFF
13-15 minutes
OFF
ON BL
ON BL
16-17 minutes
ON BL
ON BL
ON BL
18-20 minutes
Red
Green
Yellow
Maximum heating setpoint
OFF
OFF
OFF
30-36°C
ON BL
OFF
OFF
37-43°C
OFF
OFF
ON BL
44-50°C
ON BL
OFF
ON BL
51-57°C
OFF
ON BL
OFF
58-64°C
ON BL
ON BL
OFF
65-71°C
OFF
ON BL
ON BL
72-77°C
ON BL
ON BL
ON BL
78-85°C
Red
Green
Yellow
Heating ramp
OFF
OFF
OFF
0-2 °C/min
ON BL
OFF
OFF
3-4 °C/min
OFF
OFF
ON BL
5-7 °C/min
ON BL
OFF
ON BL
8-9 °C/min
OFF
ON BL
OFF
10-12 °C/min
ON BL
ON BL
OFF
13-15 °C/min
OFF
ON BL
ON BL
16-17 °C/min
ON BL
ON BL
ON BL
18-20 °C/min
Red
Green
Yellow
Maximum hot water setpoint
OFF
OFF
OFF
55°C
ON BL
OFF
OFF
60°C
OFF
OFF
ON BL
65°C
Red
Green
Yellow
Switching off burner in hot water
OFF
OFF
OFF
Fixed switch-off
ON BL
OFF
OFF
Tied to user setpoint
Red
Green
Yellow
Mains Voltage Frequency
OFF
OFF
OFF
50Hz
ON BL
OFF
OFF
60Hz