RAGGIO C
200
EN
cod. 3541V280 - Rev. 01 - 04/2021
3.4 Troubleshooting
Diagnostics
During operation, the unit can generate two types of faults:
Type F
They indicate the presence of a temporary fault. They are not indicated, but are recorded
in the Service Menu faults history. If a type F fault is not resolved independently according
to specific safety criteria, it becomes a type A fault.
Type A
They indicate the presence of a blocking fault that requires user intervention to be resol-
ved. They are indicated by lighting up of the red LEDs, the appearance of a specific win-
dow on the screen, and by the presence of a red dot on the main menu icon.
Unblocking the boiler with type A fault in progress
When a type A fault is present, the boiler can be unblocked in two ways:
1 -
Touching [RESET] when a screen similar to that shown in fig. 33 appears.
2 -
Touching the main menu icon and then [Boiler Reset] when a screen similar to that shown
in fig. 34 (main menu icon with red dot) appears.
1
fig. 33
2
fig. 34
Jul 29 2020 14:36 Connected
BAR
Anomalie de blocare
Ascunde
Resetare
Codice Anomalie: A10
Anomalia sensore di mandata
14:09 12/09/2020
Jul 29 2020 14:36 Connected
BAR
Jul 29 2020 14:36
Connected
Cronologie anomalii
Blocare ecran
Leduri
Resetare centralei
8