RAGGIO C
188
EN
cod. 3541V280 - Rev. 01 - 04/2021
100% calibration
IMPORTANT: DURING THE AUTOMATIC CALIBRATION PROCEDURE AND CHECK OF THE
CO
2
VALUE, THE FRONT CASING OF THE BOILER MUST BE CLOSED AND THE INTAKE/
FUME EXHAUST DUCTS COMPLETELY ASSEMBLED.
100% calibration, automatic
Automatic calibration can take place in some cases in the absence of a DHW or heating demand
or after a reset due to a fault and is indicated on the display by the flashing flame symbol.
100% calibration, manual
With this procedure it is possible to perform an automatic calibration on command, i.e. indepen-
dently from the control board calibration logics and therefore even when the control board does
not consider it strictly necessary
Procedure
.
• Put the boiler (preferably) in heating mode or else in DHW mode.
• Access the
[
User Menu]
• Access the
[
Service Menu]
and press
[confirm]
• Enter the password
"1234"
and confirm [
]
• Select
[Combustion Control]
• Select the parameter
[15/100% calibration]
• Type
"1"
• Press
[OK]
to confirm
• The main screen will appear with the flashing flame icon and a message
“Calibration in pro-
gress”
.
At the end of the calibration, the message
“Calibration in progress”
disappears.
The flame stops flashing and goes off or remains steady, depending on the boiler status.
OFFSET 100% calibration
With this procedure it is possible to do (if necessary) a fine setting on the automatic calibration that
the boiler performs. With this setting, the entire combustion curve can be raised or lowered.
Procedure
• Put the boiler (preferably) in heating mode or else in DHW mode.
• Access the
[
User Menu]
• Access the
[
Service Menu]
and press
[confirm]
• Enter the password
"1234"
and confirm [
]
• Select
[Combustion Control]
• Select the parameter
[15/100% calibration]
• Type
"2”
• Press
[OK]
to confirm
• The main screen will appear with the flashing flame icon and the message
[Calibration in pro-
gress].
• At the end of the calibration procedure, the display will show the screen relevant to the para-
meter
Sc12*
Modify the parameter with the + and – buttons.
After finding the correct operating point, press
[OK]
.
• The main screen will appear.
The message [Calibration in progress] disappears.
The flame stops flashing and goes off or remains steady, depending on the boiler status
* SC12
adjusts the CO
2
simultaneously at max. and min. power. By increasing the parameter va-
lue the CO
2
decreases; by decreasing the parameter value the CO
2
increases.