Use of Ø50 and Ø60 flexible pipe (for ducting only)
The chart includes the starting accessories code 041087X0 for Ø50 and code 041050X0 for Ø60.
Up to 4 m. of Ø80 mm flue can be used between the boiler and the passage with reduced width
(Ø50 or Ø60), and up to 4 m. of Ø80 mm flue on the intake (with max. length of Ø50 and Ø60
flues).
To use this width, follow the instructions below.
Enter the menu
SC
(follow the instructions given in par. “Combustion Control Menu” on page 193)
and set the parameter
SC04
to the value corresponding to the length of flue used.
For model
RAGGIO 28 C
/
For model
RAGGIO 34 C
fig. 19- Chart for flue parameter choice
fig. 18
A =
RAGGIO 28 C
Ø50 - 22 m MAX
Ø60 - 60 m MAX
RAGGIO 34 C
Ø50 - 17 m MAX
Ø60 - 45 m MAX
max 4 m
Ø80
max 4 m
Ø80
A
m
SC04
0
10
20
30
40
50
60
70
80
12
10
8
6
4
2
0
13
FLEX
Ø
50
FLEX Ø60
FLEX
Ø
50
FLEX Ø60