Test
9.
Open the ¼ turn valve of the purified water hose.
10.
Check the following lighting up of the lights I, II and III. Phase II is very short.
11.
Close the purified water valve.
12.
Check the flushing that should last 1/10 of the water suction
time.
Check of the water quality
13.
Rinse a container and the conductivity meter with purified water while light III is lighted up.
You can buy a conductivity meter by your supplier, Code CORO400C
The measured value must be lower than 50 µS.
Connection during the installation
14a.
Without storage tank
Connect the purified water hose to the flexible machine feed
hose by using if necessary the union F15/21-M20/27 (that you can
find inside the accessories bag).
14b.
With storage tank
Connect the purified water hose to
the T of the storage tank.
15.
Open the ¼ turn valve on the purified water hose.
With a storage tank:
•
At the opening of the ¼ turn valve, the storage tank fills itself till a
pressure of 4,5 Bar.
•
On duty, RO400C starts functioning when the pressure in the storage tank
goes under 3 Bar.