ELECTRICAL CONNECTION
WARNING
:
:
Danger to life due to live
components!
During all electric operation, disconnect the machine
from the network and verify the absence of
power.
The machine and its accessories must be connected
in accordance with local regulations, by a
Company specialized in electrical installations
and authorized by competent authorities
.
Before connecting the machine,
check to make sure the voltage
outlet of the mains is the same as
the voltage specified on the data
plate of the machine.
A main switch must be installed between
the mains and the machine. This safety
measure also requires that the minimum
distance between the switch contacts is at
least 3 mm and the disconnection on all
poles according to
EN 60204 (VDE 113)
.
Fuses on the main switch must be
20 A.
The mains must be wired to be able to
handle the current drawn by the
machine.The system must also be provided
with a proper ground lead in accordance
with the existings norms. The electric cable
must be of the following type
H07RN-F
.
For the right choice of the cross section
area refer to the following table:
mod.
Volt
total
power
(kW)
Current
intensit
y max
(A)
Cable
(mm²)
LP-6-8-ek
400/3
electric
13
20
2,5
steam
4
8
2,5
PLP31-38-
ek
400/3
electric
26
38
10
steam
6
12
2,5
The electrical safety of this equipment is
only assured if it is connected as follows.
It is necessary to connect the equipment to
an effective ground installation, as specified
by the electrical safety regulations in force.
Chack that this basic requirement is
complied with and, in case of doubt, ask for
a careful check of the installation by a
qualified personal.
In addition, the equipment shall be part of
an equipotential system, the effectiveness
of which should be checked according to
the regulations in force.
The connection should be made at the
screw marked by the respective label
located on the equipment back side (
).
L
630
18
0
L
P
P
L-Ingresso cavo
P-Connessione alla
cassetta elettrica
150
170
MOD.PT1500-LP31-38
MOD.
PT850-LP6-8
DIS-CAVO-PT
THE MACHINE SHALL BE
CONNECTED WITH AN EFFECTIVE
GROUND CLAMP.
The manufacturer declines any
responsibility for any damages
caused by lack of an effective
ground installation.
Summary of Contents for LP6-ek
Page 1: ...INSTRUCTIONS MANUAL POT WASHING MACHINE LP31 L ek...
Page 2: ...2...
Page 4: ...4...
Page 9: ...9 INSTRUCTIONS FOR THE USER...
Page 24: ......
Page 25: ......
Page 26: ......
Page 33: ...CONNECTIONS SCHEME Black Black Black Black Staples Black Black Staples...
Page 38: ...09 06 2017 11 45 00...
Page 39: ...09 06 2017 11 45 00...
Page 40: ...09 06 2017 11 45 01...
Page 41: ...09 06 2017 11 45 01...