6. Once the pilot is lit, continue to depress the control knob for 
30 seconds. 
7. If the pilot does not stay lit, repeat steps 4-6. 
8. If after repeating steps 4-6 unit does not light, then: 
 

* Push in control knob and turn counter clockwise to PILOT. 

 

* As you are depressing the control knob, place stick lighter into 

 

    the viewing hole on the emitter screen to manually light 

            the pilot. 

NOTE

: If pilot fails to remain lit, all valves should be closed and a waiting 

period of at least 5 minutes should pass before attempting to re-light. 
 
9. Push in and turn the control knob counterclockwise to the LO position. 
To increase the flame, push in and turn the control knob counterclockwise 
to the HI position. 

If you experience any ignition problems, please consult “Troubleshooting” on page 18. 

Caution

: Avoid inhaling fumes emitted from the heater’s first use. Smoke and odor from the   

Burning of oils used in the manufacturing will appear. Both smoke and odor will dissipate after 
approximately 30 minutes. The heater should NOT produce thick black smoke. 

Note: The burner may be noisy when initially turned on. To eliminate excessive noise from the burner, 

turn the control knob CLOCKWISE to the PILOT position. Then turn the control knob to the desired 

level (Lo to HI).

 

 
 
 
 
 
 
 
 

When Heater is ON

Emitter screen will become bright red due to intense heat. The color is more visible at night. Burner will display 
tongues of blue and yellow flame. These flames should not be yellow or produce thick black smoke, indicating an 
obstruction of airflow through the burners. The flame should be blue with straight yellow tops. If excessive yellow 
flame is detected, turn off heater and consult “Troubleshooting” on page 18. 

 
Re-Lighting

Note

: For your safety, control knob cannot be turned OFF without first depressing the control knob and then 

rotating to OFF. 

1. Turn control knob to OFF. 
2. Wait at least 5 minutes to allow gas to dissipate before re-lighting. 
3. Repeat the “Lighting” steps listed above. 

 
 
 
 
 
 

Shut Down

1. Turn control knob clockwise to PILOT. (Normally, burner will make a slight popping noise when extinguished). 
Burner will extinguish but PILOT will remain on. 
2. To extinguish PILOT, depress control knob and continue to turn clockwise to OFF position. 
3. Turn cylinder valve clockwise to OFF and disconnect regulator when heater is not in use. 

NOTE

: After use, some discoloration of the emitter screen is normal. 

 
 

 
 
 
 
 

 

 

OPERATING INSTRUCTIONS 

 

Summary of Contents for Fleur-de-lis

Page 1: ... Heaters ATTACH YOUR RECEIPT HERE Serial Number ___________ Purchase Date ______ Manufacturer Changzhou Wellife Furnace Co Ltd stions problems missing parts Before returning to your tailer call our customer service hotline at 1 866 985 7877 6 p m EST Monday Friday or email at ervice welltraveled net ...

Page 2: ...l safety information is presented in the first few pages and is also located throughout this manual Keep this manual for future reference and to educate new users of this appliance This manual should be read in conjunction with the labeling on the appliance Safety precautions are essential when any mechanical or propane fueled equipment is involved These precautions are necessary when using storin...

Page 3: ...3 SAFETY INFORMATION ...

Page 4: ...4 SAFETY INFORMATION ...

Page 5: ...KAGE CONTENTS ASSEMBLY PART DESCRIPTION QTY A Reflector Panel 3 B Center Cap 1 C Head Assembly 1 D Gas Hose 1 E Regulator 1 F Table 1 G Post 1 H Connector 1 I Tank Housing 1 J Guard Bar with LPG Tank Strap 1 ...

Page 6: ...issing or damaged do not attempt to assemble this product ESTIMATED ASSEMBLY TIME 60 minutes Tools Required for Assembly NOT included Phillips screwdriver w medium blade Leak Test Solution NOTE This heater has an Electronic Ignition and will require the installation of 1 AAA battery The battery should be installed by unscrewing the RED IGNITER BUTTON The battery is NOT included HARDWARE CONTENTS A...

Page 7: ... Housing I Hint Make sure you open the door of the Tank Housing so you will have access to the screws Place the Connector onto the top of the Tank Housing and then slide 1 M6 Washer CC and 1 M6 Spring Washer EE over the end of the screw Secure the Connector to the Tank Housing with 1 M6 Nut DD Repeat with the other 2 screws on the Connector Tighten the nuts with the Wrench HH provided Hardware Use...

Page 8: ...3 Screw the Post G onto the Connector H 4 Slide the Table F over the Post G and secure it in place with a total of 4 M6x16 Screws GG and 4 M6 Washers CC with the Allen Wrench II Hardware Used ASSEMBLY 3 4 ...

Page 9: ...els cap before assembling Note If necessary for proper alignment of reflector assembly loosen each bolt prior to further assembly and re tighten after sections are aligned 6b Slide 2 Reflector Panels A together Insert 1 M6x10 Screw KK Slide 1 M6 Washer PP over the threaded end of the screw and then loosely secure with 1 Cap Nut LL Repeat with other screws washer cap nuts ASSEMBLY 5 6a 6b ...

Page 10: ... the screws nuts on the rolled edge Hardware Used 6a b c 7 Attach the Reflector to the Head Assembly C Slide 3 M8 Washers over the threaded end of the Double End Stud NN Align the Reflector with the Double End Studs and then slide 3 M8 Washers over the end of the Double End Studs and secure the Reflector to the Head Assembly using 3 Wing Nuts MM Securely tighten the Wing Nuts but DO NOT overtighte...

Page 11: ...Assembly C to Post G Route Gas Hose D down into Post G and then align holes in Head Assembly C with holes in top of Post G Tip The control knob should be directly above the decal on the post Insert 4 M6x12 Screws FF through 4 Spring Washers EE and 4 M6 Washers CC then into holes and securely tighten with the Wrench HH Hardware Used ASSEMBLY 8 9 ...

Page 12: ...E to valve on LPG cylinder and hand tighten securely Be careful not to cross thread these connections Place LPG cylinder onto base of heater and close Tank Housing Door NOTE Use this heater only with a propane vapor withdrawal supply system See chapter 5 of the standard for storage and handling of liquefied petroleum gas ANSI NFPA 58 Your local library or fire department should have this book ASSE...

Page 13: ...n The propane cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT or the standard for cylinders spheres and tubes for transportation of dangerous goods and commission CAN CSA B339 The cylinder must have a listed overfilling prevention device The cylinder must have a connection device compatible with the conn...

Page 14: ... use and by a qualified service person at least annually If re lighting a hot heater always wait at least 5 minutes 2 Inspect the hose assembly for evidence of excessive abrasion cuts or wear Suspected areas should be leak tested If the hose leaks it must be replaced prior to operation Only use the replacement hose assembly specified by the manufacturer Lighting NOTE For initial start or after any...

Page 15: ...iminate excessive noise from the burner turn the control knob CLOCKWISE to the PILOT position Then turn the control knob to the desired level Lo to HI When Heater is ON Emitter screen will become bright red due to intense heat The color is more visible at night Burner will display tongues of blue and yellow flame These flames should not be yellow or produce thick black smoke indicating an obstruct...

Page 16: ... not be hung from the heater or placed on or near the heater 19 Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater 20 Installation and repair should be done by a qualified service person The heater should be inspected before each use and at least annually by a qualified service person 21 More frequent cleaning may be required as nec...

Page 17: ...ickly than normal Frequently check for corroded areas and repair them promptly Storage Between uses Turn Control Knob OFF Disconnect LP source Store heater upright in an area sheltered from direct contact with inclement weather such as rain sleet hail snow dust and debris If desired cover heater to protect exterior surfaces and to help prevent build up in air passages Never leave LP cylinder expos...

Page 18: ...nder is frosted over Wait until the propane cylinder warms up and defrosts Blockage in orifice Clear blockage Control knob is in OFF position Turn control knob to ON Burner flame is low Gas pressure is low Turn cylinder valve OFF and replace cylinder Outdoor temperature is less than 40 F and tank is less than full Turn cylinder valve OFF and replace cylinder Spiders and insects have nested in burn...

Page 19: ...EMENT PARTS LIST ASSEMBLY PART DESCRIPTION QTY A Reflector Panel 3 B Center Cap 1 C Head Assembly 1 D Gas Hose 1 E Regulator 1 F Table 1 G Post 1 H Connector 1 I Tank Housing 1 J Guard Bar with LPG Tank Strap 1 ...