39
17 • ROUTINE MAINTENANCE
17.2 • PLACEMENT OUT OF SERVICE
If the appliance won’t be used for a long
period of time (more than a week), it is
advisable to proceed as follows.
a)
If the appliance is equipped with Aroma
& Smoke, before cleaning, remove the
cartridges, insert the small tube in a container
full of water and run a few smoke and aroma
cycles so as to clean the tubes.
b)
Run a cleaning cycle (with Calout)* at
a suitable level to ensure the utmost
cleanliness of the chamber. If the level is not
reached, run a new cleaning cycle, this time
without calout*.
c)
Remove the can of detergent and run a
Soft cleaning cycle, using only water (use an
old can filled with water, and remember to
remove it at the end).
d)
Remove the partitions and unhook the air
deflector in the chamber to inspect the rear
area and check for any dirt deposits, which
need to be removed.
e)
Close the water supply valves
f)
Open the settings menu and select the
boiler* menu, then the boiler emptying
command and wait for the operation to be
completed.
g)
Disconnect the water supply tubes.
h)
Disconnect the appliance by pressing the
on/off knob for at least 3 seconds.
i)
Remove the shower and press the key to
drain any water left in the circuit (bring the
grip down to floor level).
j)
Disconnect the power supply and pull out
the plug
k)
Close the gas shut-off valve
l)
Disconnect the drain tube to prevent
any odours or bacteria from entering the
appliance
m)
Leave the door ajar.
n)
If a Brita filter is installed, disconnect
it from the line, the filter will need to be
replaced in the event of long-term non-use
(max. 1 year after installation).
o)
Check the wear status of the gaskets so
as to arrange for their replacement before
operation is resumed.
p)
Protect the appliance against frost to avoid
error messages when it is turned back on.
* Indication only applies to units equipped
with boiler or Calout system
90034270rev02