Clinical Features
1 - Convulsions
Convulsions are not available in the Trauma configuration of the 3G
manikins.
2 - 6 Pulses
Move the slider to the appropriate position. Moving the central slider
(5) sets the overall pulse limit shown by the red line.
7 - Secretions
Check or uncheck the boxes to activate/deactivate secretions.
When froth is activated, all other secretions are deactivated to ensure
correct fluid pressure.
Secretions (clear fluid)
−
Sweat on forehead / diaphoresis
−
Tears, both eyes
−
Ears, both
−
Nose, right side
−
Mouth, right side
−
Froth from mouth, right side.
−
Urine output
Urine
Check the box for urine
−
Normal
−
Polyuria
−
Micturition
Uncheck to disable urine.
Urine output
−
Foley catheterization
−
Urine (variable)
8 – Bleeding / Flow Rate
The number shown in the Flow box indicates the total bleeding rate
for both upper and lower bleeding ports. Flow rate is shown in ml
per min.
9 - Bleeding rate scale factor
1:1 to 1:10
To conserve blood from the manikin’s internal reservoir, set a higher
scale factor to scale down the manikin bleeding in relation to the
blood loss presented on the Instructor screen.
10 - Upper Port Bleeding
Activate the checkbox to open the upper bleeding port open. Move
slider to the left or click the ‘–‘ button to decrease bleeding rate. Move
slider to the right or click the ‘+’ button to increase bleeding rate
.
11 – Connecting Wound Modules
Wound modules can be placed on the skin. Connect the wound
modules to bleeding outlets. For information on wound setup see
section:
Setup for Simulation - Connecting Wounds Kit.
The percentage shown in the box indicates the valve opening. The
percentage can also be entered by typing the desired percentage into
the box.
12 - Select Upper Port Bleeding Type
Select bleeding type using drop down menu.
−
Venous
−
Arterial
13 - Lower Port Bleeding
To adjust lower port settings, follow instructions as stated under item 10.
The percentage shown in the box indicates the valve opening of the
lower bleeding port. The percentage can also be entered by typing the
desired percentage into the box.
14 - Select Lower Bleeding Port
Select bleeding type using drop down menu.
Bleeding
To allow the manikin to bleed realistically, the manikin has internal
reservoirs for simulated blood. See the
Manikin Setup
.
The four bleeding ports and blood flow can be adjusted independently
from the
SimMan 3G
Instructor Application:
Screenshots
−
Upper / lower bleeding ports
−
Venous / Arterial
−
Works with various wound modules and moulage kits
Bleeding Treatment:
−
Bandage
−
Pressure point
−
Tourniquet
−
Surgical Clamps
Vascular Access:
−
IV access (right arm)
−
Intraosseous access
(tibia and sternum)
Consumables and Spare
Parts:
−
Laerdal Artificial Blood
Concentrate
−
Fill Units
−
Wound modules
−
Replacement trauma arm / leg.