Left Leg to Pelvis – Cable and Tube Descriptions
Name/Label
Tube/Cable Color
Connector Description
Left Pedal
Grey cable
black with silver
coloured connector
Popliteal
Grey cable
black with silver
coloured connector
Attaching the Right Leg
Please take the same precautions as when attaching the left leg.
1 Align the right leg bolt and cables with the pelvis socket. Feed the
leg bolt and cabling through the pelvis socket.
2 Carefully push the leg in towards the pelvis to form a snug fit.
3 Secure the cables and tubes in the connector. Screw the
connector in place on the leg bolt.
4 Connect the corresponding tubes and cables as shown in the
table below:
Right Leg to Pelvis – Cable and Tube Descriptions
Name/Label
Tube/Cable Color
Connector Description
Blood Right leg
Transparent,
red tube
Black twist and
lock connector
Right leg
Black harness cable
Black rectangular
connector, 4 lead
Fluid from leg
Tube, blue
White twist and
lock connector
Air from leg
Colourless
transparent tube
White twist and
lock connector
Attaching the Left Arm
Open the torso as described in steps 1 - 4,
Opening the Torso
.
Follow the procedures listed below in reverse to detach the arms.
1 Align the left arm axle with the shoulder socket.
2 Ensure that the shoulder screw is loose enough to allow the arm
axle to slide easily into place.
3 Feed the cables from the arm axle through the shoulder socket.
4 Carefully push the arm axle into the shoulder bracket, so that the
axle is flush with the inside of the bracket.
5 Tighten the shoulder screw with the Allen wrench.
LA PULSES
BP
LA
CONV
BP
B
6 Connect the arm cables to the corresponding connection points
in the torso.
Left Arm to Torso – Cable and Tube Descriptions
Name/Label
Tube/Cable Color
Connector Description
LA Pulses
Grey cable
Black rectangular
connector, 6 lead
BP
Grey cable
Black rectangular
connector, 2 lead
Manikin Setup
Summary of Contents for SimMan 3G Trauma
Page 1: ...SimMan 3GTrauma Directions for Use www laerdal com...
Page 2: ......
Page 62: ......
Page 63: ......
Page 64: ...2012 Laerdal Medical AS All rights reserved 20 07343 Rev A...