9
SERVICE
MENU
TAMP BLOW
‐
With
TAMP BLOW
set
to
YES
,
the
tamp
is
enabled.
With
the
TAMP BLOW
set
NO,
the
tamp
is
disabled.
This
is
normally
set
to
YES
.
ALARM SELECT
‐
This
can
be
set
to
OFF
,
1 STROBE
,
2 STROBES
,
or
STK LIGHT
.
UNITS
‐
Set
this
to
IMPERIAL
(English),
or
METRIC
as
desired.
LANGUAGE
‐
This
can
be
set
to
ENGLISH
,
SPANISH
,
FRENCH
,
ITALIAN
,
or
GERMAN
.
Set
as
desired.
SPEED FOLLOWING
‐
Set
this
to
YES
if
an
encoder
is
being
used,
NO
otherwise.
ENCODER PULSE RESOLUTION
‐
If
SPEED FOLLOWING
is
set
to
YES
,
this
sets
the
number
of
encoder
pulses
per
inch
of
conveyor
(product)
travel
if
an
encoder
is
used.
This
value
can
be
set
from
25.0
to
250.0
pulses
per
inch.
When
using
an
encoder
wheel
with
a
five
inch
circumference,
and
an
encoder
with
500
pulses
per
revolution,
this
value
will
be
100.
This
value
only
needs
to
be
changed
if
the
circumference
of
the
encoder
wheel
changes,
or
if
the
encoder
resolution
is
changed.
LOW LABEL INSTALLED
‐
If
set
to
YES
,
will
allow
the
setting
of
the
LOW LABEL STOP COUNT
in
the
Advanced
menu.
ZERO DOWN TIME INSTALLED
‐
Set
this
to
YES
if
the
machine
is
being
used
in
a
Zero
Down
Time
situation,
or
NO
otherwise.
When
set
to
YES
,
it
allows
the
setting
of
the
ZERO DOWN
TIME
function
in
the
Advanced
menu.
DUAL TAMP INSTALLED -
Set
to
YES
.
SPECIFIC ACTION TAMP
‐
When
set
to
YES
,
two
product
detectors
are
required.
When
the
first
product
detector
sees
a
product,
the
tamp
selected
by
SWING TAMP FIRST
will
extend
and
apply
a
label.
When
the
second
product
detector
sees
a
product,
the
other
tamp
will
extend
and
apply
a
label.
SKIP LABELING PRODUCTS
‐
Set
this
to
YES
if
you
do
not
wish
to
label
every
product,
or
NO
otherwise.
When
set
to
YES
,
it
allows
the
setting
of
PRODUCT SKIP
in
the
Advanced
menu.
MULTIPLE LABELS ON PRODUCT
:
Set
this
to
YES
if
you
wish
more
than
one
label
to
be
applied
to
each
product
,
or
NO
otherwise.
When
set
to
YES
,
it
allows
the
setting
of
PRODUCT SKIP
in
the
Advanced
menu.
I/O DEFINE DISPLAY:
See
the
Inputs/Outputs
section.