Mascot FT, Heating Only, Boiler
Page 71
Question
Answer
Burner dose not ignite
when the hot water is
opened.
Make sure that the ON/OFF button on the Control Display has been turned
ON.
If the monitor on the Control Display is blank, make sure the power cord is
plugged and 4A fuses on the main controller in the units are good.
Make sure that there is water supplied to the unit. The unit activates once
the inlet water flow is over 0 gpm.
Make sure the cold and hot water lines are not plumbed in reverse side.
Make sure that the cold water and gas supply lines are opened.
Make sure that the water lines are not frozen.
Water is not hot enough.
Check that the setting temperature on the unit is not too low
Make sure that the filter in the cold water supply line is not clogged with
debris.
Make sure that the gas supply type is correct.
Check the supply and manifold gas pressures are in accordance with
specifications.
Make sure that the water flow sensor with three wires has been properly
connected on the top of heat exchanger.
Water is too hot.
Make sure that the setting temperature on the unit is not too hot.
Make sure that the filter in the cold water supply line is not clogged with
debris.
Make sure that the gas supply type is correct.
Hot water temperature
fluctuates at the opened
tap.
Make sure that the filter in the cold water supply line is clean.
Make sure that the gas supply type is correct.
Check the supply gas pressure is sufficient.
The blower is still
operating after the
combustion stops.
This is normal because the blower keeps operating for 1 minute to vent
(exhaust) the flue gas from the chamber once the combustion has
stopped.
Temperature Rise
too Quickly
Occurs when supply water temperature in heat exchanger rises faster
than 2°F per second during the first two minutes the burner is on.
Automatically resets after a few minute delay or using manual reset on
Control Display. See message displayed TEMPERATURE SENSOR and
follow procedure for loose connections.
Abnormal sounds come
from unit during opera-
tion.
A leak of combustion gas between sealed chamber and exhaust tube
inside the unit. Call a qualified service technician for evaluation.
Improper venting termination, make sure that the venting termination
complies with specification.
Check the supply gas pressure is sufficient. Insufficient gas pressure will
cause unstable burner flame and noise.
SECTION 7. Trouble Shooting
7.1 Diagnostics
Summary of Contents for mascot ft MFTHW
Page 52: ...LAARS Heating Systems Page 50 4 19 Control Board Electrical Diagram Control Board ...
Page 53: ...Mascot FT Heating Only Boiler Page 51 4 20 Ladder Diagram ...
Page 71: ...Mascot FT Heating Only Boiler Page 69 6 2 Fault Tree Analysis 1 Flame detection ...
Page 81: ...Mascot FT Heating Only Boiler Page 79 ...
Page 83: ...Mascot FT Heating Only Boiler Page 81 ...
Page 85: ...Mascot FT Heating Only Boiler Page 83 ...
Page 87: ...Mascot FT Heating Only Boiler Page 85 ...
Page 89: ...Mascot FT Heating Only Boiler Page 87 ...
Page 91: ...Mascot FT Heating Only Boiler Page 89 ...
Page 93: ...Mascot FT Heating Only Boiler Page 91 ...
Page 94: ...LAARS Heating Systems Page 92 This page intentionally left blank ...
Page 95: ...Mascot FT Heating Only Boiler Page 93 This page intentionally left blank ...