Key

Model ORDER

No.  Description

No.

PART NO.

                                  FUEL SYSTEMS
1

Oil Burner Assembly

2000

L0060000

1

Oil Burner Assembly

3000

L0060100

2

Oil Filter (Not Shown)

All

P0065100

3

Oil Filter Cartridge (Not Shown)

All

P0065500

4

3/8” Oil Line, Pump to Filter

All

10430402

                            ELECTRICAL SYSTEM
5

Thermostat

All

R0318800

6

Thermostat Knob

All

R0010700

7

Thermostat Dial

All

H0048400

8

Thermostat Cover

All

10388300

9

Thermostat Back

All

10368000

10

Thermostat Base Plate

All

10362000

11

Pressure Switch, 1-10 PSI

All

R0045400

12

Siphon Loop Cover

All

10403400

13

Siphon Loop Assembly

All

R0057800

14

High-Limit Switch Assembly

All

R0023200

15

High-Limit Switch, 135°F

All

R0022700

16

High-Limit Switch, 150°F

All

R0012700

17

High-Limit Switch Harness (115V)

All

R0057500

18

High-Limit Switch Harness

All

R0057700

19

High-Limit Switch Cover

All

10401100

20

Switch Cover

All

E0078300

21

ON/OFF Switch

All

E0078200

22

Oil Burner Harness

All

R0057600

23

Connector Elbow 90°

All

P0059800

                                  WATER SYSTEMS
24

Heat Exchanger Assembly, Complete

2000

10927101

24

Heat Exchanger Assembly, Complete

3000

10927102

25

Heat Exchanger

2000

10927001

25

Heat Exchanger

3000

10927002

26

Inlet/Outlet Header

All

10403700

27

End Cap  (1/2” tap)

All

10403900

28

End Cap  (No tap)

All

10406100

29

End Cap  (1/4” tap)

All

10403800

30

Tee Baffle (5)

2000

10926901

30

Tee Baffle (5)

3000

10926902

31

End Baffle (2)

2000

10387702

31

End Baffle (2)

3000

10387703

32

Tube Gaskets  (12)

All

S0063400

34

Grommet (2 Required)

All

S0098800

35

Brass Plug,  3/4”  (1)

All

P0027000

36

Drain Valve Extension

All

P0059900

37

Drain Plug,  1/4”  (3)

All

P0026800

38

By-Pass Assembly

All

R0020600

39

By-Pass Valve Rod

All

S0074300

40

By-Pass Valve Disc

All

S0074200

41

By-Pass Valve Rod Retainer

All

S0008700

42

By-Pass Valve Spring

2000

S0061300

42

By-Pass Valve Spring

3000

S0061300

43

Flange & Gasket Assembly

All

R0031900

44

Flange, 1 1/2"

All

10309200

45

Flange Gasket, 1 1/2"

All

S0053100

46

Flange Sleeve, 1 1/2"

All

S0028000

47

Flange Bolt

All

F0031700

48

Gasket

All

S0065300

Key

Model ORDER

No.  Description

No.

PART NO.

 FIRE BOX & JACKET COMPONENTS

49

Burner Tube Gasket

All

N0006600

50

Burner Support Bracket

All

10392000

51

Burner Compartment Door

2000

10412203

51

Burner Compartment Door

3000

10412204

52

Fire Box Plug

All

T0020700

53

Fire Box Cover Plate

All

10425800

54

Gap Spacer  (Return)

All

10401000

55

Flue Collector Assemby

All

10406301

55

Flue Collector Assemby

All

10406302

56

Flue Top Assembly

2000

10405001

56

Flue Top Assembly

3000

10405002

57

Inner Stack

All

10390000

58

Flue Collector Shield

2000

10404501

58

Flue Collector Shield

3000

10405002

59

Vent Blade  (10)

All

10319300

60

Gap Spacer  (In/Out)

All

10400900

61

Hold Down Clip

All

10401200

62

Fire Box

2000

T0020500

62

Fire Box

3000

T0020600

63

Fire Box Cover  (2)

2000

10400801

63

Fire Box Cover (2)

3000

10400802

OIL BURNER PARTS & COMPONENTS (Not Shown)
Air Tube Screw

All

F0004300

Pilot Bracket Screw

All

F0031300

End Air Shutter

All

N0000200

Bulk Air Band

All

N0000300

Air Tube Gasket

All

N0000800

Motor, 1/7 H.P. , 3450 RPM

All

N0001000

Blower Wheel 4- 1/4” x 3- 7/16”

All

N0001400

Flexible Coupling

All

N0001500

Fuel Unit, Two Stage

All

R0140100

Pump Outlet Fitting

All

N0002000

Connector Tube Assembly

All

N0002200

Ignition Transformer

All

R0140200

Contact Spring Terminals

All

N0002600

Air Tube Combination

All

N0002900

Nozzle Line Electrode Assembly

All

N0003100

Electrode Clamp

All

N0003500

Electrode Rod & Tip

All

N0004000

Burner Head & Screws

All

N0004500

Burner Head

2000

N0004700

Burner Head

3000

N0007700

Delavan Nozzle,  2.25

3000

N0007500

Delavan Nozzle, 1.65

2000

N0007600

Primary Control

All

R0140300

Honeywell  Cad Cell

All

N0006100

By-Pass Plug

All

N0007000

By-Pass Plug

All

N0007100

1/8” Burner Head Plug

All

P0026100

1/4” Burner Head Plug

All

P0026800

 OPTIONAL EQUIPMENT

64

Pressure Relief Valve, 3/4" NPT, 75 PSI

All

R0040400

Chimney Cap - 9" (Not Shown)

All

D0014900

For more information:
Telephone:
  Main: (415)382-8220  Order Fax: (800)526-3928

Customer Service: Ext. 245   Warranty/Service: Ext. 260    Literature Requests: Ext. 237

Pool Systems Address:  21 Pimentel Ct., Novato, CA 94949  Mailing Address:  P.O. Box 6101, Novato, CA 94948-6101
Web Address: http://www.jandy.com/
International:  480 S. Service Rd. West, Oakville, Ontario, Canada L6K 2H4  (905)844-8233 voice (905)844-2635 fax

SECTION 6.
Parts List for Model DP
Oil-Fired Heater

Summary of Contents for DP2000

Page 1: ...or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT T...

Page 2: ...re 10 3B Setting the Time Clock 11 3C Winter Shutdown 12 3D Periodic Maintenance 12 SECTION 4 Maintenance 4A Trouble Shooting 12 4B Cleaning the Heat Exchanger 13 4C Trouble Shooting Guide 13 4D Opera...

Page 3: ...s and packages the heater before delivering it to the freight carrier Immediately file any claim for damage against the freight carrier 2B Assembly and Location Only use the XL 3 heater with pools fil...

Page 4: ...prove access for service and maintenance Make the change before locating and connecting the heater Follow these step by step instructions and Figure 3 to reverse the heat exchanger 1 Remove the contro...

Page 5: ...nd connect it to the header where the drain plug was removed 18 Replace the gap spacers siphon loop cover and rubber plugs and grommets 19 Install the T baffles on the gap spacers to match the screw h...

Page 6: ...ny change in the amount of draft in the combustion chamber can affect the flame characteristics An approved barometric draft control must be used on all indoor installations to maintain a clean and co...

Page 7: ...n on the decal on the end of the fuel unit Remove the large hex head fitting and insert the plug Figure 9 Combustion Air Indoor Installation Lift from bottom of Storage tank to Total Tubing Length All...

Page 8: ...aded 1 1 4 iron pipe or 1 1 2 copper tubing see Fig 12 Connect the pool heater between the pump and filter and the pool or spa If the system flow rate exceeds 60 gpm 228 lpm install a manual bypass va...

Page 9: ...warranty IMPORTANT 1 Provide the automatic chlorinator with an anti siphoningdevicetopreventchlorinesiphoning into the heater after the pump shuts off 2 Wire the electric chlorinator so it cannot ope...

Page 10: ...ol compartment The wirenut has a tag on it carrying wiring instructions Position the field installed wires away from the inner panel 2K Special Pressure Switch A special pressure switch is required if...

Page 11: ...ry three more re sets If there is still no ignition have a qualified oil service technician bleed the fuel line and check for ignition problems When the heater does fire oil which is in the firebox wi...

Page 12: ...y fouling the external heat exchanger passages causing incompletecombustion 3D Periodic Maintenance Oil the oil burner motor every six months Use SAE 30 non detergent motor oil in both holes Check the...

Page 13: ...Use a bottle brush to brush down between the tube fins toward the firebox The ash can be softened for easier removal by lightly dampening with a wet brush Do not let water get in the firebox 5 Reach...

Page 14: ...he piping the contacts in the heater pressure switch close 2 The heater thermostat calls for heat completing the circuit between the two thermostat terminals on the primary control of the oil burner 3...

Page 15: ...ing spark at the electrodes go to step 3 3 Lift the ignition transformer and make sure the motor rotates freely If it does not rotate freely replace the motor If the motor is internally binding replac...

Page 16: ...e heater will smoke Generally the C02 reading will be above 12 when not enough air is provided Lacking proper instruments a temporary fuel air adjustment can be made Close the end shutter and then slo...

Page 17: ...move one 2 000 ohm resistor wire from the primary control The primary should lock out on safety within 25 seconds 12 After the primary locks out the ohmmeter pointer should move to near the 50 mark on...

Page 18: ...KET COMPONENTS 49 Burner Tube Gasket All N0006600 50 Burner Support Bracket All 10392000 51 Burner Compartment Door 2000 10412203 51 Burner Compartment Door 3000 10412204 52 Fire Box Plug All T0020700...

Page 19: ...el DP Oil Fired Heater Page 19 51 53 52 1 49 50 63 62 29 26 46 44 47 34 12 13 20 21 11 4 22 30 33 32 25 27 37 36 25 29 55 54 56 57 58 59 60 8 9 5 7 6 30 64 29 18 39 40 42 15 19 31 24 17 23 43 45 61 48...

Page 20: ...eplacementofdefective parts and shall not include transportation to or from factory fieldlabor andconsequentialorincidentaldamages Ship inoperativepartsorcompleteheaterwithSerialNumberand purchasedate...