8. Mandatory Maintenance and Check-up Operations
▪
Replace group gaskets
▪
Replace diffuser screens
▪
Clean auto-fill probe
▪
Check vacuum breaker for
proper operation
▪
Inspect water inlet valve
▪
Check brew temperature
▪
Checking the pre-infusion and
delivery pressure
▪
Check all switches for proper
operation
▪
Check/note water hardness
(Water quality must be within the
range of parameters specified in
the chapter on Installation,
otherwise warranty is voided)
▪
Check filter basket condition
▪
Expansion valve inspection
▪
Spring stem inspection
▪
Cam inspection
▪
Check for cylinder complete
saturation
These operations are in addition to the Maintenance and Periodic Cleaning Operations as specified in Chapter 6.
The following maintenance and check-up operations sould be carried out by a qualified technician.
The time required for the periodic maintenance is determinated by the quantity of daily work and/or coffee consumption.
N.B. These periodic maintenance operations are not covered by warranty.
▪
Check the condition of the inside of boilers and if necessary rinse out with a proper cleaning product allowed for food and beverage
appliances.
EVERY THREE/FOUR MONTHS
EVERY 3 YEARS (in addition to the above)
▪
Replace portafilter baskets
▪
Inspect vacuum breaker
▪
Inspect electrical wiring
condition
▪
Inspect boilers safety switches
▪
Replace over-pressure valve
(safety valve)
▪
Accurate control of the
tightness at 2,4Nm of each
cable on the terminal block
▪
Replacement of piston seals
▪
Check for tightness of the lever
mechanism screws
Version S:
▪
Overhaul of steam taps
Version X and 90:
▪
Inspection of steam proportional
valve
▪
Replacement of piston stem
seals
▪
Replacement of spring stem
guide rings
▪
Replacement of cam wheel
▪
Replacement of lever mechanism
rollers
EVERY YEAR (in addition to the above)
EVERY 2 YEARS (in addition to the above)