Display
Operating Procedure
Description
“Technical” Programming
Menu 93.2°C
Enter Password
0000
1
After entering the password and accessing the "Technician" programming menu, rotate the Encoder Knob until
the following is displayed.
Menu 93.2°C
Coffee Boiler
Settings
2
Press the Encoder Knob to access the menu.
Menu 93.2°C
Coffee Boiler 1
ENABLED
3
Press the Encoder Knob to access the menu, rotate the Encoder Knob to choose between
ENABLED and DISABLED,
press the Encoder Knob to confirm the option.
Menu 93.2°C
CB1 Temperature
Current:95.5
Target:94.5
4
Press the Encoder Knob to access the menu, rotate the Encoder Knob to modify the value, press the Encoder
Knob to confirm the desired value.
Menu 93.2°C
Steam Boiler
Settings
• This parameter enables the technician
to set various parameters of the coffee
boiler.
• The boiler temperature is measured in
the boiler’s most critical point, where
the temperature fluctuation is the
largest.
• The temperature of the water inside the
group head is kept constant by the group
mass. Though the boiler temperature
may fluctuate slightly, that of the water
inside the group is constant.
• In order to properly calibrate the
temperature of each espresso, it
is important that you measure the
temperature of the water inside the
group using an external temperature
measuring device. The difference
between the temperature shown on the
display and the measured temperature
can be compensated with the “Coffee T.
offset” parameter.
• The OFFSET parameter is used to
Coffee Boiler
Menu 93.2°C
TeaPump For Brew
NO TEA PUMP
Menu 93.2°C
Coffee Boiler
Settings