EN
12
3. Installation
LA FIGURA AFFIANCO DESCRIVE COME
COLLEGARE OGNI FILO ALLA SPINA.
RISPETTARE ANCHE LE NORME FEDERALI,
STATALI O LOCALI VIGENTI.
MODELLO/SERIE GRUPPO
V/Hz
POTENZA
NOMINALE
(W)
INPUT
NOMINALE
(A)
POTENZA
CALDAIA
CAFFE’
POTENZA
CALDAIA
VAPORE
POTENZA
TOTALE
DIMENSIONE CAVO
ALIMENTAZIONE
ELETTRICA (mm²)
LEVA X
2GR
AC220-240V/60Hz
AC208-240/60Hz
AC380-415/50Hz
5664
24,7
2664
3000
5664
15
PER DETTAGLI
3GR
7793
3793
4000
7793
VEDERE I
COLLEGAMENTI
ELETTRICI
ATTENZIONE
AC220-240V/60Hz
AC208-240/60Hz
AC380-415/50Hz
24
33,8
20,5
33
THE DETAILS ON THE LEFT DESCRIBE
HOW TO CONNECT EACH WIRE TO THE PLUG.
RESPECT ALSO THE LOCAL SAFETY
REGULATIONS.
MODEL/SERIES
GROUP
V/Hz
RATED
POWER
(W)
RATED
INPUT
(A)
COFFEE
BOILER
WATTAGE
STEAM
BOILER
WATTAGE
TOTAL
WATTAGE
POWER CORD
SIZE (mm²)
LEVA X
2GR
AC220-240V/60Hz
AC208-240/60Hz
AC380-415/50Hz
5664
24,7
2664
3000
5664
15
SEE ELECTRICAL
3GR
7793
3793
4000
7793
CONNECTIONS
FOR DETAILS
WARNING
AC220-240V/60Hz
AC208-240/60Hz
AC380-415/50Hz
24
33,8
20,5
33
1 X BLU (NEUTRO)
1 X MARRONE (FASE)
1 X GIALLO & VERDE (TERRA)
CAVO ALIMENTAZIONE ELETTRICA:
5 X FILI
380V
1 X MARRONE (FASE)
1 X GRIGIO (FASE)
1 X NERO (FASE)
1 X BLU (NEUTRO)
1 X GIALLO & VERDE (TERRA)
3 X FILI
220V
POWER CORD:
1 X BLUE (NEUTRAL)
1 X BROWN (PHASE)
1 X YELLOW & GREEN (GROUND)
5 X WIRES
380V
1 X BROWN (PHASE)
1 X GRAY (PHASE)
1 X BLACK (PHASE)
1 X BLUE (NEUTRAL)
1 X YELLOW & GREEN (GROUND)
3 X WIRES
220V
HERE THE POSITION OF THE POWER CORD AND
WATER INLET HOSES
FROM
∅
80 TO
∅
100 mm
FROM
∅
3 in. TO
∅
4 in.
HERE THE POSITION WHERE WE
SUGGEST TO MAKE THE HOLE
ON THE TABLE
155 mm
6,1 in.
14,5 mm
0,6 in.
POSITION OF THE LEGS MACHINE
777 mm (2 groups)
30,5 in. (2 groups)
977 mm (3 groups)
38 in. (3 groups)
HERE THE POSITION
OF THE DRAIN TUBE
95 mm
3,7 in.
452 mm
17,8 in.
100 mm
3,9 in.
340 mm
13,4 in.
395 mm
15,5 in.
62 mm
2,4 in.
180 mm
7,1 in.
70 mm
2,7 in.
POSITION OF THE LEGS MACHINE
673 mm (2 groups)
26,5 in. (2 groups)
873 mm (3 groups)
34,4 in. (3 groups)
Fig. 3 - Installation guide
WARNING
The machine is intended to be
permanently connected to fixed
wiring, and it is mandatory that a
residual current device (RCD) with a
rated residual operating current not
exceeding 30mA is installed.
WARNING
The Coffee Boiler and Steam
Boiler contain water at elevated
temperature. Water temperature
over 125°F / 52°C can cause severe
burns instantly or death from scalding
(Coffee Boiler 207°F/97°C - Steam
Boiler 256°F / 124°C)
WARNING
Replace fuses with the same size,
type and rating F1 = 2A, 250V
WARNING
This machine should not be installed
in kitchens.
Summary of Contents for LEVA X