EN
88
Display
Operating Procedure
Description
“Technical” Programming
(only on ABR espresso machine models)
• This parameter allows the
technician
to
view and manually change each dose for
each key.
• For greater accuracy and consistency of
the doses, it is recommended that you
set each key.
Program Dose
Scales
G1B1 Brew Ratio
1:2.00
5
Press the button T1 or T2 to view the dose of each key. Pressing the button T3, the dose value will blink. Use
the button T1 or T2 to change the value, press the button T3 to confirm the desired value.
G1 PF Mass
800.0g
6
Press the button T1 or T2 to view the portafilter mass of each group. Pressing the button T3, the value will
blink. Use the button T1 or T2 to change the value, press the button T3 to confirm the desired value.
G1 Coffee Mass
14.0g
7
Press the button T1 or T2 to view the coffee mass of each group. Pressing the button T3, the value will blink.
Use the button T1 or T2 to change the value, press the button T3 to confirm the desired value.
G1B3 Mode
CONTINUOUS
8
Press the button T3
to enter the menu,
then navigate using T1and T2 to choose between
CONTINUOUS
or
3 SEC
RINS
.
G1 Doses
Settings
Group Dose
Settings