Appendix D: Glossary 

ADC 

Analog  to  Digital  Converter,  internal  controller  hardware  to  convert 
measurements into digital signals for processing. 

AGM 

Battery that the electrolyte is held in separators between the plates, fitted with 
a pressure relief value so it only vents under unusual circumstances. 

Auto EQ/Refresh After 

It’s the time the battery needs to remain connected to the charger to initiate a 
refresh cycle. The actual setting depends on the battery and application. 

Bootload 

Setting a microprocessor in a condition where you load or update its firmware. 

Bulk Charge 

The  first  stage  of  charge  cycle  where  the  charger  is  outputting  maximum 
current  to  recharge  the  battery  as  quickly  as  possible.  Stage  completes  when 
the voltage reaches a nominal 75-80% state of charge. 

Charger Interface 

PC software application required to communicate with the MPC35 controller. 

Power Module 

The core module that converts AC power into DC power suitable for charging a 
battery. 

Configuration 

Setting  the  necessary  adjustments  of  the  MPC35  controller  to  suit  the  battery 
and charging application. 

dV/dt 

Rate of change of voltage, slope of the change in voltage against time. 

Equalize 

Maintenance  function  using  a  low  constant  current  charge  to  ensure  all  cells 
inside the battery have similar voltage. 

EQ/Refresh Current 

The  percentage  of  the  nominal  charge  current  that  is  used  for  the  refresh, 
second constant current stage, actual setting depends on the battery type and 
application. 

EQ/Refresh Duration 

The duration of the refresh charge, it is only constant current or a combination 
of constant current and constant voltage. 

EQ/Refresh Lockout 

Timer  to  prevent  an  equalize  charge  starting  after  a  normal  charge  until  the 
battery has had time to cool down. 

EQ/Refresh  Max  Cell 
Voltage 

The maximum charger output voltage during the refresh charge. Can either be 
a  trip  or  a  second  constant  voltage  stage  depending  on  the  setting  of 
EQ/Refresh Constant Voltage. 

Finishing Charge 

The stage(s) that follow the bulk charge to return the battery form 80 to 100% 
state of charge which must be done more slowly than the bulk charge stage. 

Firmware 

Computer code that is embedded in a microprocessor 

GEL 

Battery that the electrolyte is trapped in a silica gel, fitted with a pressure relief 
value so it only vents under unusual circumstances 

IUI 

Charge  profile  with  constant  current,  then  constant  voltage,  the  constant 
current control and automatic termination. 

LED 

Light emitting diode, a solid state light source that does not wear out. 

Summary of Contents for MXHF

Page 1: ...964 Instruction Drawing Number P25 LMXHF 1 Tel 847 299 1188 Fax 847 299 3061 Revision A00 Rev Date 03 14 ECN 20355 La Marche Manufacturing Company www lamarchemfg com MXHF MXHF MXHF MXHF Motive Power...

Page 2: ...at neither liquids nor any wet material come in contact with any internal components Do not operate this unit outside the input and output ratings listed on the unit nameplate Do not use this unit for...

Page 3: ...alling the product Verify that you have all the necessary parts per your order for proper assembly CAUTION Failure to properly file a claim for shipping damages or provide a copy of the claim to La Ma...

Page 4: ...2 2 Making the AC Input Connections 9 2 2 1 Bus Bar Selection 9 2 2 2 Auxiliary Power Supply Voltage Selection 10 2 2 3 AC Input Connections 10 2 3 Relay Configuration 11 2 4 Alarms 11 2 4 Alarms 12 2...

Page 5: ...8 1 System Requirements 19 3 8 2 Installation 19 3 8 3 Operator Access Level Control 19 3 8 4 Charger Interface Tabs 19 3 8 5 Charge Profile Factory Settings 20 3 8 6 Alarm Factory Settings 22 4 Servi...

Page 6: ...180ADC These chargers may be powered with 208 240VAC single phase or three phase For 380 480VAC three phase only Understanding the Model Number The MHHF model number is coded to describe the options...

Page 7: ...ative humidity of 5 to 95 1 2 Placement of the MXHF The preferred installation is where the charger s can be located on a table or shelf protected against accidental contact with the lift truck or its...

Page 8: ...t the base of the MXHF onto the mounting bracket 3 When fitting the battery cable ensure the locking screw is installed Mounting Bracket Side Mount 1 Fix the Mounting Bracket to the wall using a type...

Page 9: ...Follow three easy steps to verify or configure proper AC input for the MXHF 2 2 1 Bus Bar Selection Configuring the Bus Bars on the AC filter board negates the need to rewire the AC inputs to the pow...

Page 10: ...g 208 240V J5 480V J6 2 2 3 AC Input Connections The AC input cables are terminated onto the AC filter board via a five way terminal strip marked A B C for phases 1 2 and 3 D for neutral and E for ear...

Page 11: ...Open RY2 J108 Pin 2 3 3 Charge Active Normally Closed Open RY3 J113 Pin 2 3 4 Alarm 1 Normally Open Closed RY4 J115 Pin 2 3 5 Alarm 2 Normally Open Closed RY5 J106 Pin 2 3 6 Not used RY6 J117 Pin 2 3...

Page 12: ...urgent module count in the PC application monitor tab then the charger will stop If the urgent module count is set to one then the Charger is configured without redundancy and a single fault will sto...

Page 13: ...to be disconnected mid cycle the toggle switch must be first set to STOP This will stop the charge and log a partial cycle in the charge log but allows safe disconnection of the battery Reversed Batte...

Page 14: ...rings up the MXHF product page 5 Mini USB socket the USB port allows the PC application to talk to MPC35 controller 6 Inlet Filter required for the power modules to be cooled with clean air 7 Stop Sta...

Page 15: ...f the battery This option gives ability to charge different type of batteries using only one MXHF charger Each battery will require an APC module The APC module monitors battery voltage and temperatur...

Page 16: ...the completion of the normal charge until the equalize lockout time has expired normally 4 hours If the battery is unplugged before the lockout expires the request for Equalize will be cleared To ena...

Page 17: ...harger As show in figure 8 the LCD will display the following settings Battery Voltage Battery Type Battery Amp Hour and Maximum Battery Current 3 5 2 LCD View in the Charging State While the battery...

Page 18: ...een LED Lamp illuminated Charge terminated by the user No LEDs illuminated Urgent alarm ON charge terminated Red and Amber LEDs flashing Red and Green LED Lamps flashing Non urgent alarm ON charge not...

Page 19: ...or troubleshooting monitoring and retrieving alarm and charge logs 3 8 1 System Requirements Charger Interface software has the following minimum system requirements Microsoft XP SP3 Windows Vista Win...

Page 20: ...ful for determining usage trends and battery health BMM Alarm Log View and save the alarm log from a BMM battery module Alarm Log Displays all recorded charger and battery alarms for analysis and savi...

Page 21: ...mp Comp factor 3mV degC cell Charge Profile Name AGM Charge Profile Type IUI Stage 1 Current 16A 100Ah 100 Stage 2 Voltage 2 37 V C Stage 3 Current 3 04A 100Ah 19 Stage 3 Min dV dt 3mV 15min cell Stag...

Page 22: ...Daily Schedule Stop Configuration Error APC Electrolyte Level Low Output Fuse No Output Current Module Over Temperature APC Communication Fail APC Voltage Imbalance Controller ADC Fail Over Discharge...

Page 23: ...wer modules only run during charging and are speed controlled If the charger output is small the fans will only be turning slowly At full power there is a considerable requirement for cooling air and...

Page 24: ...ir inlet and outlet Configuration Error Charger cannot provide the target output current Check the controller configuration matches the quantity of power modules installed add power module if necessar...

Page 25: ...ger configuration matches the battery check the battery for problems Finishing Charge Timeout The finishing charge part of the cycle is longer than expected Check the charger configuration matches the...

Page 26: ...ice arrangements Should minor adjustments be required the local La Marche Sales Representative should be contacted to provide this service All sales are final Only standard LaMarche units will be cons...

Page 27: ...ut clearing any protective devices ENVIROMENTAL Operating Temperature 14 to 158 F 10 to 70 C max output power is de rated above 122 F 50 C Storage Temperature 4 to 158 F 20 to 70 C Relative Humidity 5...

Page 28: ...7 5 4 3 9 14 2 10 6 7 6 16 2 12 2 8 9 23 3 17 8 12 5 NA 20 4 14 2 110 7 9 5 9 4 3 14 3 11 7 8 2 16 8 13 5 9 8 28 8 19 4 13 8 NA 22 5 15 9 120 8 6 6 4 4 7 15 6 12 7 8 9 18 3 14 3 10 5 NA 20 6 14 9 NA...

Page 29: ...t time Equalize Maintenance function using a low constant current charge to ensure all cells inside the battery have similar voltage EQ Refresh Current The percentage of the nominal charge current tha...

Page 30: ...100 Stage 1 Timeout The maximum time the charger will stay in bulk charge stage Stage 2 Voltage The setting for the constant voltage stage set in accordance with the battery technology depending on w...

Page 31: ...31 Appendix E Document Control and Revision History Part Number 128964 Instruction Number P25 LMXHF 1 Issue ECN 20355 03 14...

Reviews: