background image

(P/N)762.128 Rev B EN 05/10 • © copyright 2009-2010 

Kaba Mas LLC

page 4

The 3000 and 3715 Entry Device is designed with keyhole slots for ease 
of mounting and battery replacement. 

1. Install the two #8-32 shoulder screws (US) or the M4-0.7 shoulder 
  screws (metric) to mount the Entry Device to the door.
2. Feed the key pad cable through the spindle cable hole from the front 
  of the safe door. Leave approximately 2 inches (50mm) of the cable 
  extended out the front of the container door, to allow for 
  battery replacement.
3. Position the Entry Device over the mounting screws and then side the 
  Entry Device down onto the mounting screws. (Figures 1 & 2)
4. Ensure that the Entry Device cable is running through the channel at 
  the back of the lock.

INSTALLING BATTERIES

1. Slide the keypad housing up and carefully pull away from mounting surface to expose battery compartment.

CAUTION! 

Hold onto the battery connector to avoid pulling the wires out of the board.

2. Connect a new 9-Volt alkaline battery to the battery connector.
3. Push the battery and the leads completely into the battery compartment.
4. Repeat procedure for second battery ( 3000 only).
5. Carefully position the keypad over the mounting screws 
  and slide the keypad housing down. Ensure there are no wires 
  or cables trapped between the Entry Device and the safe door.

Keyhole Slots

Figure 1

Figure 2

9 Volt Battery

Keyhole Slots

3000

3000

3715

3715

3000 AND 3715 ROUND ENTRY DEVICE

Summary of Contents for 3000

Page 1: ...ELECTRONIC ENTRY DEVICE INSTALLATION INSTRUCTIONS FOR BASIC AND GARD SERIES...

Page 2: ...15 ENTRY DEVICE 4 3035 3125 ROUND ENTRY DEVICE 5 Swingbolt instructions Dead bolt instructions 3710 ANGULAR ENTRY DEVICE 7 Additional instructions 3710 keypad replacement 3750 3750 K 3750KE 3190 ENTRY...

Page 3: ...l is recommended BASIC TOOLS AND MATERIALS REQUIRED Medium Phillips head screwdriver 2 recommend magnetized tip Small flat file or deburring stone Tape measure or ruler ESD wrist band PREPARATION FOR...

Page 4: ...P N 762 128 Rev B EN 05 10 copyright 2009 2010 Kaba Mas LLC page 2 DIAL RING FRONT HOUSING BASE MOUNTING TEMPLATE...

Page 5: ...P N 762 128 Rev B EN 05 10 copyright 2009 2010 Kaba Mas LLC page 3 8130 ENTRY DEVICES MOUNTING TEMPLATE DO NOT SCALE...

Page 6: ...nting screws Figures 1 2 4 Ensure that the Entry Device cable is running through the channel at the back of the lock INSTALLING BATTERIES 1 Slide the keypad housing up and carefully pull away from mou...

Page 7: ...4 Insert the spindle into the keypad and route the cable in the groove of the spindle 5 Slide the bearing plate p n 2674 over the cable and press onto the fasteners on the Entry Device NOTE It is imp...

Page 8: ...ay from the safe door CAUTION Hold onto the battery connector to avoid pulling the wires out of the board 3 Connect a new 9 Volt alkaline battery to the battery connector 4 Push the battery and the le...

Page 9: ...at the back of the lock Refer to lock installation instructions which are available at www kaba mas com ALTERNATE INSTALLATION The option adapter plate p n 3716 may be used to mount the 3710 Entry De...

Page 10: ...ck of the keypad Figure 8 5 Rotate the key pad approx 30 counter clockwise and place keypad bushings into the large openings on the dial plate Then turn the key pad clockwise until the blocking pin cl...

Page 11: ...se until the key pad is vertical 10 The spindle should protrude between 300 350 8 9 mm through the safe door 11 Slide the cable protector p n 2754 over the cable and spindle until the flat side rests...

Page 12: ...fer to lock installation instructions which are available at www kaba mas com 8130 alternate method tamper evident for vds approval The 8130 Entry Device comes with the mylar portion of the keypad una...

Page 13: ...spindle to a length of 820 20 8mm plus the door thickness Figure 14 NOTE the spindle must be deburred 3 Install the knob assembly using the two 8 32 X 5 16 phillips pan screws 4 Install the lock with...

Reviews: