background image

(P/N)762.128 Rev B EN 05/10 • © copyright 2009-2010 

Kaba Mas LLC

page 9

DEAD BOLT/SPRING BOLT

1. Mount the dial plate (p/n 3752) centered on the through hole (Figure 6). Attach the dial plate with the two mounting screws US 8-32 
(US) or the M4-0.7 (metric). .
2. Measure total mounting thickness (door thi mounting plate). (Figure 9.)
3. Cut the spindle to a length of 1.06” (27 mm) plus the total mounting thickness.

NOTE: 

the spindle must be deburred .

4. Insert the spindle into the keypad, and route the cable in the groove of the spindle (Figure 7). 
5. Route the cable either under the spindle or between the circuit board and the spindle.
6. Slide the bearing plate (p/n 2674) over the cable, and press onto the fasteners on the Entry Device (Figure 7). 

NOTE: 

It is important to make sure the cable will not rub on the dial plate after assembly.

7. Feed the Entry Device’s cable and spindle through the spindle/cable hole from the front of the safe door.

WARNING: 

Spring and blocking pin are NOT installed when Entry Device is used with either the dead bolt or spring bolt locks. 

8. Rotate the key pad approx. 30° counter-clockwise and place keypad bushings into the 
9. Then turn the key pad clockwise until the key pad is vertical. 
10.  The spindle should protrude between .300" - .350" (8 - 9 mm) through the safe door.
11.  Slide the cable protector (p/n 2754) over the cable and spindle, until the flat side rests against the inside of safe door. Route the 
    cable through the groove of the cable protector.
12.  Gently pull on the cable to assure that there is no excess cable in the spindle hole that would rub on the metal door.
13.  Install the lock with the bolt extended onto the spindle. Refer to lock installation instructions 
    which are available at www.kaba-mas.com.

BATTERY INSTALLATION

1. If installed, remove black plastic battery compartment cover (located at the bottom of the
  keypad) by gently pulling downward on its handle.
2. Allow the battery connector and its attached leads to drop down and out of the battery 
  compartment. If it does not drop, gently pull on the battery connector until it does. 

CAUTION! 

Hold onto battery terminal connector to avoid pulling the wires out of housing.

3. Connect a new 9-Volt alkaline battery to the battery connector.
4. Push the battery and the leads completely into the battery compartment.
5. Install the battery cover by placing one side of the cover in position and then pressing the
  other side into position with your finger.

Figure 9

Figure 9

Dead/Spring Bolt

DOOR

MOUNTING PLA

TE

Total Mounting Thickness = door thickness

+ mounting plate

Summary of Contents for 3000

Page 1: ...ELECTRONIC ENTRY DEVICE INSTALLATION INSTRUCTIONS FOR BASIC AND GARD SERIES...

Page 2: ...15 ENTRY DEVICE 4 3035 3125 ROUND ENTRY DEVICE 5 Swingbolt instructions Dead bolt instructions 3710 ANGULAR ENTRY DEVICE 7 Additional instructions 3710 keypad replacement 3750 3750 K 3750KE 3190 ENTRY...

Page 3: ...l is recommended BASIC TOOLS AND MATERIALS REQUIRED Medium Phillips head screwdriver 2 recommend magnetized tip Small flat file or deburring stone Tape measure or ruler ESD wrist band PREPARATION FOR...

Page 4: ...P N 762 128 Rev B EN 05 10 copyright 2009 2010 Kaba Mas LLC page 2 DIAL RING FRONT HOUSING BASE MOUNTING TEMPLATE...

Page 5: ...P N 762 128 Rev B EN 05 10 copyright 2009 2010 Kaba Mas LLC page 3 8130 ENTRY DEVICES MOUNTING TEMPLATE DO NOT SCALE...

Page 6: ...nting screws Figures 1 2 4 Ensure that the Entry Device cable is running through the channel at the back of the lock INSTALLING BATTERIES 1 Slide the keypad housing up and carefully pull away from mou...

Page 7: ...4 Insert the spindle into the keypad and route the cable in the groove of the spindle 5 Slide the bearing plate p n 2674 over the cable and press onto the fasteners on the Entry Device NOTE It is imp...

Page 8: ...ay from the safe door CAUTION Hold onto the battery connector to avoid pulling the wires out of the board 3 Connect a new 9 Volt alkaline battery to the battery connector 4 Push the battery and the le...

Page 9: ...at the back of the lock Refer to lock installation instructions which are available at www kaba mas com ALTERNATE INSTALLATION The option adapter plate p n 3716 may be used to mount the 3710 Entry De...

Page 10: ...ck of the keypad Figure 8 5 Rotate the key pad approx 30 counter clockwise and place keypad bushings into the large openings on the dial plate Then turn the key pad clockwise until the blocking pin cl...

Page 11: ...se until the key pad is vertical 10 The spindle should protrude between 300 350 8 9 mm through the safe door 11 Slide the cable protector p n 2754 over the cable and spindle until the flat side rests...

Page 12: ...fer to lock installation instructions which are available at www kaba mas com 8130 alternate method tamper evident for vds approval The 8130 Entry Device comes with the mylar portion of the keypad una...

Page 13: ...spindle to a length of 820 20 8mm plus the door thickness Figure 14 NOTE the spindle must be deburred 3 Install the knob assembly using the two 8 32 X 5 16 phillips pan screws 4 Install the lock with...

Reviews: