(P/N)762.128 Rev B EN 05/10 • © copyright 2009-2010
Kaba Mas LLC
page 9
DEAD BOLT/SPRING BOLT
1. Mount the dial plate (p/n 3752) centered on the through hole (Figure 6). Attach the dial plate with the two mounting screws US 8-32
(US) or the M4-0.7 (metric). .
2. Measure total mounting thickness (door thi mounting plate). (Figure 9.)
3. Cut the spindle to a length of 1.06” (27 mm) plus the total mounting thickness.
NOTE:
the spindle must be deburred .
4. Insert the spindle into the keypad, and route the cable in the groove of the spindle (Figure 7).
5. Route the cable either under the spindle or between the circuit board and the spindle.
6. Slide the bearing plate (p/n 2674) over the cable, and press onto the fasteners on the Entry Device (Figure 7).
NOTE:
It is important to make sure the cable will not rub on the dial plate after assembly.
7. Feed the Entry Device’s cable and spindle through the spindle/cable hole from the front of the safe door.
WARNING:
Spring and blocking pin are NOT installed when Entry Device is used with either the dead bolt or spring bolt locks.
8. Rotate the key pad approx. 30° counter-clockwise and place keypad bushings into the
9. Then turn the key pad clockwise until the key pad is vertical.
10. The spindle should protrude between .300" - .350" (8 - 9 mm) through the safe door.
11. Slide the cable protector (p/n 2754) over the cable and spindle, until the flat side rests against the inside of safe door. Route the
cable through the groove of the cable protector.
12. Gently pull on the cable to assure that there is no excess cable in the spindle hole that would rub on the metal door.
13. Install the lock with the bolt extended onto the spindle. Refer to lock installation instructions
which are available at www.kaba-mas.com.
BATTERY INSTALLATION
1. If installed, remove black plastic battery compartment cover (located at the bottom of the
keypad) by gently pulling downward on its handle.
2. Allow the battery connector and its attached leads to drop down and out of the battery
compartment. If it does not drop, gently pull on the battery connector until it does.
CAUTION!
Hold onto battery terminal connector to avoid pulling the wires out of housing.
3. Connect a new 9-Volt alkaline battery to the battery connector.
4. Push the battery and the leads completely into the battery compartment.
5. Install the battery cover by placing one side of the cover in position and then pressing the
other side into position with your finger.
Figure 9
Figure 9
Dead/Spring Bolt
DOOR
MOUNTING PLA
TE
Total Mounting Thickness = door thickness
+ mounting plate