INVENTORY OF CONTENTS
1. The WS-9118U weather station (Figure 1)
2. One TX7U remote temperature/humidity sensor (Figure 2)
3. Mounting hardware
4. Instruction manual and warranty card.

ADDITIONAL EQUIPMENT (not included)
1. Three fresh AA 1.5V batteries for the indoor weather station.
2. Two fresh AA 1.5V batteries for the remote temperature/

humidity sensor.

3. One Philips screwdriver for mounting.

ABOUT WWVB (Radio Controlled Time)
The NIST (National Institute of Standards and Technology-Time
and Frequency Division) WWVB radio station is located in Ft.
Collins, Colorado, and transmits the exact time and date signal
continuously throughout the United States at 60 kHz. The signal
can be received up to 2,000 miles away through the internal
antenna in the Weather Station. However, due to the nature of
the Earth’s Ionosphere, reception is very limited during daylight
hours. The weather station will search for a signal every night
when reception is best. The WWVB radio station derives its
signal from the NIST Atomic clock in Boulder, Colorado. A team
of atomic physicists is continually measuring every second, of
every day, to an accuracy of ten billionths of a second per day.
These physicists have created an international standard,
measuring a second as 9,192,631,770 vibrations of a Cesium-
133 atom in a vacuum. For more information on the atomic clock
and WWVB please see the NIST website at http://www.boulder.
nist.gov/timefreq/stations/wwvb.htm.

QUICK SET-UP GUIDE
Hint: Use good quality Alkaline Batteries and avoid
rechargeable batteries.
1. Have the indoor weather station and remote temperature/

humidity sensor 3 to 5 feet apart.

2. Batteries should be out of both the indoor weather station

and remote temperature/humidity sensor units for 10 minutes.

3. Place the batteries into the remote temperature/humidity

sensor first then into the indoor weather station.

4. DO NOT PRESS ANY BUTTONS FOR 15 MINUTES.

In this time the indoor weather station and remote temperature/
humidity sensor will start to talk to each other and the display
will show the indoor temperature/humidity, outdoor temperature/
humidity, heat index and dew point. If the indoor weather station
does not display all information after the 15 minutes please retry
the set up as stated above. After all information has been
displayed for 15 minutes you can place your sensors outdoors
and set your time.

Important Notes on Set-up and Operation

The remote temperature/humidity sensor should be placed
in a dry, shaded area.

Fog and mist will not harm your remote temperature/humidity
sensor but direct rain must be avoided.

The remote temperature/humidity sensor has a range of 330

TABLE OF CONTENTS

Topic

Page

Inventory of Contents/Additional Equipment

3

About WWVB

4

Quick Set-Up Guide

4

Detailed Set-Up Guide
Battery installation

5

Program Mode
  Program Sequence and Default Settings

7

  Function Keys

7

  Setting the LCD Contrast

7

  Setting the Time Zone

7

  Daylight Saving Time Setting

8

  Radio-controlled Time Setting

9

  12/24-hour Time Setting

9

  Setting the Time

10

  Setting the Year, Day and Month

11

  Setting the Snooze

11

  Setting the Forecast Sensitivity

12

Features
  Weather Forecast Icons and Tendency Arrows

13

  Indoor Temperature, Humidity, & Comfort

14

  Level Indicator
  Outdoor Temperature, Humidity, Heat Index, Dewpoint

14

  Minimum & Maximum Records

15

  (Indoor, Outdoor, & Resetting)
  Moon Phase

17

  Time Alarm

17

  EL Backlight

18

Adding Remote Temperature

18

Humidity Sensors (Optional)
Mounting

19

Troubleshooting

21

Maintenance & Care

22

Specifications

22

Warranty Information

24

feet. Any walls that the signal will have to pass through will
reduce distance. An outdoor wall or window can have up to 30
feet of resistance and an interior wall can have up to 20 feet of
resistance. Your distance plus resistance should not exceed
330 ft. in a straight line.

The remote temperature/humidity sensor transmits a signal
every minute.  After the batteries have been installed, the indoor
weather station will search for the signal for a duration of 4
minutes. If there is no temperature or humidity reading in the
OUTDOOR LCD after 4 minutes, make sure the units are within
range of each other, or repeat the battery installation procedure.

If a button is pressed before the indoor weather station receives
the signal from the remote temperature/humidity sensor, you
will need to follow the battery installation procedure again.

To complete the set up of your new wireless weather station after
the 15 minutes have passed please follow the steps that follow in
the Detailed Set-Up Guide.

DETAILED SET-UP GUIDE

BATTERY INSTALLATION

A. REMOTE TEMPERATURE/HUMIDITY SENSOR

1. Remove the batteries from all existing units in operation.
2. Using a screwdriver, unscrew and open the battery cover

located at the front of the outdoor temperature/humidity sensor.

3. Replace the battery cover and screw.

Time LCD

Moon Phase and
Date LCD
Indoor LCD

Forecast LCD

Outdoor LCD

Heat index and
Dew point LCD

Figure 1

Figure 2

RH

F

%

Outdoor temperature/
humidity sensor

Mounting Bracket

SIZE AA LR6

SIZE AA LR6

Battery cover

Battery

compartment

Summary of Contents for WS-9118U

Page 1: ...h 53 FCC DISCLAIMER FCC ID OMO 01RX Receiver OMO 01TX transmitter This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation R ...

Page 2: ...emperature humidity sensor should be placed in a dry shaded area Fog and mist will not harm your remote temperature humidity sensor but direct rain must be avoided The remote temperature humidity sensor has a range of 330 TABLE OF CONTENTS Topic Page Inventory of Contents Additional Equipment 3 About WWVB 4 Quick Set Up Guide 4 Detailed Set Up Guide Battery installation 5 Program Mode Program Sequ...

Page 3: ...is the darkest 3 Press and release the ALM button to select the level you desire 4 Press and release the SET button to confirm and advance to the Time Zone setting IV TIME ZONE SETTING 1 Press and hold the SET button for 3 seconds 2 LCD will show in the TIME LCD and the number setting will flash 3 Press and release the SET button again 4 The time zone will flash in the DATE LCD 5 Press and release...

Page 4: ...he SET button for 3 seconds 2 LCD will show in the TIME LCD and the number setting will flash 3 Press and release the SET button ten times 4 Sn will appear in the DATE LCD and a number will be flashing next to it 5 Press and release the ALM button to select the duration of the snooze Note The snooze can be set for 0 to 30 minutes in 5 minute increments If 0 minutes is selected pressing the SNZ CH ...

Page 5: ...EAT INDEX AND DEW POINT RECORDS 1 Press and release the OUT MIN button once MAX appears with the outdoor temperature indicating that the maximum temperature and the time and date of occurrence are displayed The maximum record will display for 30 seconds before returning to the normal display mode 2 Press and release the OUT MIN button again once while MAX temperature is still displayed twice other...

Page 6: ...hat the indoor weather station is able to receive WWVB signals from the desired location Also extreme and sudden changes in temperature will decrease the accuracy of the indoor weather station and changes in elevation will result with inaccurate weather forecasting for the next 12 to 24 hours These changes will require a 12 to 24 hour wait before obtaining reliable data To achieve a true temperatu...

Page 7: ...nology Ltd provides a 1 year limited warranty on this product against manufacturing defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this product To receive warranty service the purchaser must contact La Crosse Technology Ltd for problem determinatio...

Page 8: ...rieure 4 N APPUYEZ SUR AUCUNE TOUCHE PENDANT 15 MINUTES Pendant ce temps la station météo intérieure et le capteur hygrothermique commenceront à dialoguer la station affichant la température et l humidité intérieures et extérieures ainsi que l indice thermique et le point de rosée Si la station météo n affiche pas toutes ces informations dans les 15 minutes répétez la procédure de paramétrage déta...

Page 9: ...L heure affiche 12 00 et la recherche du signal WWVB commence En cas de réception réussie d habitude la nuit l heure correcte sera affichée le fuseau horaire par défaut est EST Vous devrez alors régler le fuseau horaire à votre fuseau horaire local MODE PROGRAMMATION Remarque sur la programmation Après que 15 secondes se sont écoulées ou si la touche SNZ CH est pressée en mode Programmation l appa...

Page 10: ...remplacé 1 Appuyez sur la touche SET pendant 3 secondes 2 LCD s affiche à la section HEURE de l écran LCD et le chiffre clignote 3 Appuyez encore cinq fois sur la touche SET 4 Les chiffes de l heure clignotent à la section HEURE de l écran LCD 5 Appuyez sur la touche ALM pour faire avancer les chiffes de l heure 6 Appuyez sur la touche SET pour confirmer le réglage de l heure et passer au réglage ...

Page 11: ...rosée sont alors calculés à partir des relevés de température et d humidité reçus IV RELEVÉS MINIMUM ET MAXIMUM DETEMPÉRATURE DE L INDICE THERMIQUE ET DU POINT DE ROSÉE La station WS 9118U enregistre les températures MINIMUM et MAXIMUM et le jour et l heure de relevé pour les deux modes intérieur et extérieur A AFFICHAGE DES RELEVÉS DE TEMPÉRATURE ET HUMIDITÉ INTÉRIEURES 1 Appuyez sur la touche IN...

Page 12: ...es distants différents le s modèle s de capteur thermo hygrométrique que vous choisirez seront accompagnés d une fiche d instructions qui vous guidera dans l installation complète des capteurs Les instructions simplifiées suivantes concernent l installation de base des capteurs distants avec la station WS 9118U Ces capteurs distants supplémentaires sont disponibles chez le revendeur de cet apparei...

Page 13: ...n météo intérieure de façon à ce que la trajectoire en ligne droite du signal ne traverse pas plus de deux ou trois murs Problème Les températures ne s accordent pas lorsque les deux unités sont placées côte à côte Solution Chaque capteur thermo hygrométrique est conçu avec une précision de 2 degrés de plus ou de moins dans des conditions normales Il est possible de constater une différence de tem...

Page 14: ...e pas les frais d installation ou de désinstallation d une installation fixe le paramétrage normal ou les réglages les litiges basés sur les malversations du vendeur ou les variations de performance résultant des circonstances relatives à l installation LA CROSSE TECHNOLOGY N ACCEPTE AUCUNE RESPONSABILITÉ POUR LES DOMMAGES FORTUITS CONSÉCUTIFS PUNITIFS OU AUTRES DOMMAGES SIMILAIRES RELATIFS À L UT...

Page 15: ...evamente con los pasos para la puesta en funcionamiento descritos anteriormente Después de que los datos sean visualizados durante 15 minutos usted puede colocar sus sensores afuera al aire libre y ajustarles la hora Notas Importantes para la Puesta en Funcionamiento y la Operación de la unidad El sensor remoto de temperatura humedad debe ser colocado en un lugar sombreado y seco La niebla y la br...

Page 16: ...eado 4 Pulse y suelte el botón SET para confirmar y pasar al programa de ajuste de la Zona Horaria IV AJUSTE DE LA ZONA HORARIA 1 Pulse el botón SET durante 3 segundos 2 El símbolo LCD será visualizado en la pantallita de la HORA TIME LCD y el número empezará a relampaguear 3 Pulse y suelte nuevamente el botón SET 4 La zona horaria titilará en el DATE LCD 5 Pulse y suelte la tecla ALM para selecci...

Page 17: ... de ajuste de la función del snooze X AJUSTE DE LA FUNCION DEL SNOOZE 1 Pulse el botón SET durante 3 segundos 2 El símbolo LCD será visualizado en la pantallita de la hora TIME LCD y el número a ser ajustado empezará a relampaguear 3 Pulse diez veces el botón SET 4 El símbolo Sn aparecerá en la pantallita DATE LCD y el numeró aparecerá titilando al lado de este símbolo 5 Pulse el botón ALM para se...

Page 18: ...te 30 segundos antes de que la pantalla se devuelva al modo de visualización normal 2 Pulse nuevamente el botón IN HR una sola vez mientras que el símbolo MAX continúe siendo visualizado sino dos veces más El símbolo MIN aparecerá visualizado con la temperatura interior indicando que la mínima temperatura y la hora y fecha de su grabación están siendo visualizadas en la pantalla Los registros de l...

Page 19: ...na Esta luz se iluminara durante 10 segundos cada vez que se pulse cualquiera tecla 2 La iluminación E L no puede ser encendida constante porque se agotaran las pilas VIII AGREGANDO MÁS SENSORES REMOTOS DE LA TEMPERATURA HUMEDAD OPCIONAL La estación WS 9118U es capaz de recibir señales de 3 diferentes sensores remotos de la temperatura humedad El modelo s de los sensores es remotos que usted haya ...

Page 20: ...eteorológica en interiores este ubicada al menos a 6 pies 2 metros de distancia de cualquier aparato eléctrico como televisores ordenadores o cualquier otro reloj controlado por señales de radio 3 Retire las pilas durante cinco minutos reinsértelas y deje la unidad sola toda la noche entera sin tocar ninguno de sus botones 4 Si aun así persisten los problemas contacte a La Crosse Technology Proble...

Page 21: ...n o inspección del aparato le será cobrado al cliente El propietario deberá pagar los costos de envío para enviar su producto de La CrosseTechnology Ltd hasta un centro de servicio autorizado de La Crosse Technology Ltd La Crosse Technology Ltd le pagará los costos razonables de envío de retorno al propietario del producto Su garantía de La Crosse Technology Ltd cubre todos los defectos del materi...

Reviews: