TM00358 Rev. A
Chapter 6 - Turret Purging
L-3 WESCAM
October 2007
All Rights Reserved
105
16. Connect the valve extension to the turret's purge valve.
17. Reconnect the air hose chuck to the valve extension.
18. Verify that nitrogen is flowing into the turret. Place your ear to the rear turret door and listen for pressurized
flow.
19. Confirm that the turret's breather valve is working by listening for escaping air.
20. Leave the system to purge for a minimum of one hour.
21. Check the color of all quadrants in the turret's humidity indicator:
21a. If all quadrants are not blue, continue the purge for another 30 minutes.
21b. Otherwise, all quadrants are blue and the turret is now purged.
22. When the turret is confirmed to be fully purged, turn the regulator counter-clockwise and adjust hose
pressure to 0 kg/cm
²
(psi).
23. Disconnect the air hose chuck from the valve extension.
24. Disconnect the valve extension from the turret's purge valve and replace the cover cap.
25. Reconnect the air hose chuck to the valve extension.
26. Close the nitrogen supply tank valve fully, then open the regulator to bleed off pressure.
27. Disconnect the regulator assembly from the nitrogen supply tank.
28. Return the turret back to the Stow position.
29. If stored in a carrying case, return the regulator assembly to the case.
30. Install the main breaker to restore power and steering control to the turret.