background image

17

Parts List

Item                        Description

Part Number

1

Regulator (Propane Gas)

21722

Regulator (Natural Gas)

20218

2

Adapter, Hose, 1/4 NPT x 9/16-18 (Propane Gas)

01098

Adapter, Hose, 1/2 NPT x 1/2 NPS (Natural Gas)

02894*

3

Hose, 1/4 in. x 10 ft. (Propane Gas)

20496

Hose, 1/2 in. x 10 ft. (Natural Gas)

20243*

4

Valve, Manual Shut Off (Natural Gas)

05548

5

Nipple, 1/2 in. x 1 1/2 in. (Natural Gas)

02420

6

Bushing, 1/2 in. x 1/4 in. (Natural Gas)

01519

7

Nipple, 1/4 in. x 2 in. (Natural Gas)

03071

8

Ell

01300

9

Screen, Inlet

20391

10

Nut, Jam

20185

11

Valve, Pilot Safety

07966

12

Valve, Main Burner

20229

Valve, Main Burner (CV250 Natural Gas)

09698

13

Ell, Street, 1/4 NPT

01425

14

Bushing

04817

15

Igniter, Piezo

20280

17

Base - CV100

20202

Base - CV250

20203

18

Plug, 1/8 NPT

09271

19

Connector, Pilot Line, Gas Control Outlet

20454

20

Connector, Pilot Line for Pilot Head, Inlet

20455

21

Orifice, Pilot (Propane Gas)

20212

Orifice, Pilot (Natural Gas)

20213

22

Manifold, 1/4 NPT x 6 in.

20228

23

Orifice, Burner - CV100 (Propane Gas)

20187

Orifice, Burner - CV100 (Natural Gas)

20186

Orifice, Burner - CV250 (Propane Gas)

20189

Orifice, Burner - CV250 (Natural Gas)

20188

24

Thermocouple, 18 in.

03555

25

Bracket, Thermocouple

20194

26

Burner - CV100

20206

Burner - CV250

20231

27

Electrode with Wire (Piezo)

20184

28

Ring, Heat Shield - CV100

20305

Ring, Heat Shield - CV250

20255

29

Barrel - CV100

20210

Barrel - CV250

20230

30

Top - CV100

20078

Top - CV250

20064

Miscellaneous C

Components ((Not IIllustrated)

Description

Part Number

Screw, #8 x 3/8

07288

* Optional Accessories for Natural Gas Units

NOTE: The complete barrel assembly may be ordered.  Order part #20211 for CV100 and #20235 for CV250.

The barrel assembly consists of items 29 and 30.

Summary of Contents for CV100

Page 1: ...ay have call us toll free at 1 800 345 7200 Owner s Manual and Instructions Workman Convection Construction Heaters ATTENTION ALL USERS This heater has been tested and evaluated by C S A International...

Page 2: ...property damage personal injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily injury or b...

Page 3: ...empted by anyone who is not so qualified See page 6 for definition of the necessary qualifications Contact your local L B White distributor or the L B White Co Inc for assistance or if you have any qu...

Page 4: ...Propane Natural Propane Natural Gas Gas Gas Gas M Mo od de el l Ventilation Air Required to Support Combustion CFM Net Weight lbs Shipping Weight lbs Dimensions Inches L x W x H Minimum Safe Distances...

Page 5: ...eath Symptoms of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing Asphyxiation H Hazard Some p people c cannot s smell w well S Some p people c cannot smell t the...

Page 6: ...is not directly exposed to water spray rain or dripping water 7 Do not locate fuel gas containers or fuel supply hoses anywhere near the discharge outlet of the heater 8 Do not block air intakes or di...

Page 7: ...a gas leak is detected check the components involved for cleanliness and proper application of pipe compound before further tightening Furthermore tighten the gas connections as necessary to stop the...

Page 8: ...and maintain the heater by using this Owner s Manual Make sure you know how to shut off the gas supply to the building and also to the individual heater Contact your fuel gas supplier if you have any...

Page 9: ...Fully open the manual main burner valve located between pilot safety control and burner the main burner will light WARNING Burn H Hazard Close the manual main burner valve before lighting the pilot F...

Page 10: ...up and shut down instructions and warnings are available at no cost 1 Before cleaning shut off all gas supply valves 2 The heater should have dirt or dust removed periodically a Before each use give...

Page 11: ...dataplate or in the specification section of this owner s manual 2 Does the pressure reading agree with that given on the dataplate If so no further checking or adjustment is required Proceed to secti...

Page 12: ...e above procedure ATTENTION The pilot orifice hole is drilled to a specific diameter to match the fuel and gas pressure being used Do not push sharp instruments into the orifice holes Clean the orific...

Page 13: ...be located at the center line of the pilot orifice and positioned so it sparks across to the outside edge of the pilot orifice holder See Fig 4 4 Verify that the electrode s ceramic body is not cracke...

Page 14: ...ilot line See remedy for same cause in Problem 1 stay lit when pilot button is released Insufficient time allowed for pilot Hold in pilot button for 30 seconds to allow proper light to heat up thermoc...

Page 15: ...se of igniting the main burner and heating the thermocouple Works directly in conjunction with the thermocouple PILOT SAFETY GAS CONTROL VALVE A gas control valve which is held open by electrical powe...

Page 16: ...Parts Identification Parts Schematic 16 LP GAS HOSE AND REGULATOR ASSEMBLY NATURAL GAS HOSE AND REGULATOR ASSEMBLY 1 2 3 4 5 1 2 2 3 6 7 8 9 10 11 14 13 15 12 19 18 17 20 23 22 24 21 26 25 27 28 30 29...

Page 17: ...NPT 09271 19 Connector Pilot Line Gas Control Outlet 20454 20 Connector Pilot Line for Pilot Head Inlet 20455 21 Orifice Pilot Propane Gas 20212 Orifice Pilot Natural Gas 20213 22 Manifold 1 4 NPT x 6...

Page 18: ...the d date o of p purchase b by the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months...

Reviews: