9. Light according to instructions on heater or within

owner's manual.

10. Make sure the heater has the proper gas regulator for

the application.  A regulator must be connected to the

gas supply so that gas pressure at the inlet to the gas

valve is regulated within the range specified on the

dataplate at all times.  Contact your gas supplier, or

the L.B. White Co., Inc. if you have any questions.

11. This heater can be configured for use with either

propane gas vapor withdrawal or natural gas.  Consult

the heater’s dataplate for the gas configuration of the

specific heater.  Do not use the heater in an propane

liquid withdrawal system or application.  If you are in

doubt, contact the L.B. White Co., Inc.

12. Take time to understand how to operate and maintain

the heater by using this Owner’s Manual.  Make sure

you know how to shut off the gas supply to the

building and also to the individual heater.  Contact

your fuel gas supplier if you have any questions.

13. Any defects found in performing any of the service or

maintenance procedures must be eliminated and

defective parts replaced immediately.  The heater

must be retested by properly qualified service

personnel before placing the heater back into use.

8

HOSE AND REGULATOR ASSEMBLY

PROPANE GAS SUPPLY 

CONTAINER VALVE

REGULATOR

HOSE

HOSE ADAPTER

TO

 HEA

TER

1. Always use approved pipe thread compound suitable

for use with propane gas or natural gas on the

threaded connections.

2. Assemble the components together according to the

figure.  This view is to show general assembly of the

components only.

3. Tighten all connections securely.

4. Check  aall  cconnections  ffor  ggas  lleaks  uusing  aapproved

gas lleak ddetectors.

FIG. 1

Summary of Contents for CV100

Page 1: ...ay have call us toll free at 1 800 345 7200 Owner s Manual and Instructions Workman Convection Construction Heaters ATTENTION ALL USERS This heater has been tested and evaluated by C S A International...

Page 2: ...property damage personal injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily injury or b...

Page 3: ...empted by anyone who is not so qualified See page 6 for definition of the necessary qualifications Contact your local L B White distributor or the L B White Co Inc for assistance or if you have any qu...

Page 4: ...Propane Natural Propane Natural Gas Gas Gas Gas M Mo od de el l Ventilation Air Required to Support Combustion CFM Net Weight lbs Shipping Weight lbs Dimensions Inches L x W x H Minimum Safe Distances...

Page 5: ...eath Symptoms of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing Asphyxiation H Hazard Some p people c cannot s smell w well S Some p people c cannot smell t the...

Page 6: ...is not directly exposed to water spray rain or dripping water 7 Do not locate fuel gas containers or fuel supply hoses anywhere near the discharge outlet of the heater 8 Do not block air intakes or di...

Page 7: ...a gas leak is detected check the components involved for cleanliness and proper application of pipe compound before further tightening Furthermore tighten the gas connections as necessary to stop the...

Page 8: ...and maintain the heater by using this Owner s Manual Make sure you know how to shut off the gas supply to the building and also to the individual heater Contact your fuel gas supplier if you have any...

Page 9: ...Fully open the manual main burner valve located between pilot safety control and burner the main burner will light WARNING Burn H Hazard Close the manual main burner valve before lighting the pilot F...

Page 10: ...up and shut down instructions and warnings are available at no cost 1 Before cleaning shut off all gas supply valves 2 The heater should have dirt or dust removed periodically a Before each use give...

Page 11: ...dataplate or in the specification section of this owner s manual 2 Does the pressure reading agree with that given on the dataplate If so no further checking or adjustment is required Proceed to secti...

Page 12: ...e above procedure ATTENTION The pilot orifice hole is drilled to a specific diameter to match the fuel and gas pressure being used Do not push sharp instruments into the orifice holes Clean the orific...

Page 13: ...be located at the center line of the pilot orifice and positioned so it sparks across to the outside edge of the pilot orifice holder See Fig 4 4 Verify that the electrode s ceramic body is not cracke...

Page 14: ...ilot line See remedy for same cause in Problem 1 stay lit when pilot button is released Insufficient time allowed for pilot Hold in pilot button for 30 seconds to allow proper light to heat up thermoc...

Page 15: ...se of igniting the main burner and heating the thermocouple Works directly in conjunction with the thermocouple PILOT SAFETY GAS CONTROL VALVE A gas control valve which is held open by electrical powe...

Page 16: ...Parts Identification Parts Schematic 16 LP GAS HOSE AND REGULATOR ASSEMBLY NATURAL GAS HOSE AND REGULATOR ASSEMBLY 1 2 3 4 5 1 2 2 3 6 7 8 9 10 11 14 13 15 12 19 18 17 20 23 22 24 21 26 25 27 28 30 29...

Page 17: ...NPT 09271 19 Connector Pilot Line Gas Control Outlet 20454 20 Connector Pilot Line for Pilot Head Inlet 20455 21 Orifice Pilot Propane Gas 20212 Orifice Pilot Natural Gas 20213 22 Manifold 1 4 NPT x 6...

Page 18: ...the d date o of p purchase b by the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months...

Reviews: