Mechanical safety
Mechanical safety
Flown congurations
The Kara IIi rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the
guidelines of BGV-C1.
2006/42/EC: Machinery Directive species a safety factor of 4 against the rupture. The own deployments described in
this manual achieve a safety factor of
4 or more
.
Refer to Soundvision for the safety factor of a specic deployment.
The
safe limit
gives the maximum number of elements for which the safety factor is compliant with the 2006/42/
EC: Machinery Directive, within the use dened in this manual and regardless of the other deployment parameters (site
angles, inter-element angles, etc.).
The
maximum limit
gives the maximum number of elements for which the safety factor can be compliant with the
2006/42/EC: Machinery Directive, when the other deployment parameters provide the best mechanical conditions.
For mixed arrays refer to your Soundvision model.
Kara IIi
conguration
rigging accessory
safe limit
maximum limit
Flown
KARAIIi-BUMP + M-BARi (optional) +
rigging plates
12
24
KARAIIi-BUMP + M-BARi + KARAIIi-
rigging plates
12
Flown with pullback
KARAIIi-RIGBAR × 2 + rigging plates
12
Ceiling-mounted
KARAIIi-FIXBRACKET / KARAIIi-
TILTB rigging plates
3
SB18 IIi
conguration
rigging accessory
safe limit
maximum limit
KARAIIi-BUMP + rigging plates
12
16
Flown
KARAIIi-BUMP + M-BARi + rigging
plates
8
16
Flown with pullback
KARAIIi-RIGBAR × 2 + rigging plates
4
6
Ceiling-mounted
KARAIIi-FIXB rigging plates
2
SB18 IIi + Kara IIi
conguration
rigging accessory
safe/maximum limit
Ceiling-mounted
KARAIIi-TILT + KARAIIi-FIXB rigging
plates
1 SB18 IIi +
3 Kara IIi
36
Kara IIi owner's manual (EN) version 2.0