Rigging system description
To calculate the site angle of the rst enclosure, subtract the splay angle from the site angle of KARAIIi-BUMP.
-5° splay angle
0° KARAIIi-BUMP site angle
0-(-5) = +5° Kara IIi site angle
+5° splay angle
0° KARAIIi-BUMP site angle
0-5 = -5° Kara IIi site angle
In
Soundvision
, only the positive splay angles can be selected between KARAIIi-BUMP and Kara IIi (
Elements
panel).
They are labeled as follows:
angle in Soundvision splay angle
5°
0°
7.5°
+2.5°
10°
+5°
It is recommended to set a 0° splay angle (5° in Soundvision) between the rst Kara IIi and KARAIIi-BUMP.
By doing this, the Kara IIi axis is parallel to KARAIIi-BUMP.
Nine pickup points are available on the central bar for site angle adjustment. They are compatible with Ø19 mm
shackles WLL 3.25 t (two provided). Four holes are available to secure M-BARi in position A or B, to provide additional
pickup points. Refer to
(p.24).
FRONT
A B
A B
1 2
4
3
5 6 7 8 9
Kara IIi owner's manual (EN) version 2.0