G O M + 표 준 형 - 영 문
43
After gas pipe construction, a gas leak
check must be done.
y
In case of gas leak, it may cause an explosion
that induces serious bodily harm or property
damage.
Please complete the gas pipe construction
after checking the required gas for the unit.
y
If you use gas other than the one specified in the
boiler lower right hand rating plate, it may cause
incomplete combustion that can cause a fire or an
explosive ignition.
When using a gas container, place the
container in the cool shady place away from
direct sunlight in the outdoors and fix the
container properly to prevent tipping.
y
An explosion may occur.
Pipe material should adhere to the KS standards.
Gas Pipe
Carbon steel pipe for pipe usage, copper or copper alloy pipe, metal
flexible pipe approved by gas component part inspection testing.
Heating Pipe
Copper pipe or copper alloy + insulator, XLPE pipe + insulator
Hot Water Pipe
Copper or copper alloy + insulator, XLPE pipe + insulator
Gas meter, at least 3 level for below 20,000kcal/h and at least 5
level
for over 25,000kcal/h.
Pipe Material
Summary of Contents for KDB-101GOM+