When using a indoor space that is not an
exclusively boiler room, please install the
required inflow/outflow type (FF).
y
There is a danger of Carbon Monoxide (CO) gas
poisoning when installing the unit in an indoor
space not exclusively for the boiler where it should
be installed in air close type (FF).
Please check to make sure that the location
has sufficient space to prevent fire and the
walls and ceiling are safe against fire.
y
The unit should be installed near a non-
combustible wall.(if combustible wall then install a
heat-proof panels.)
y
The side of the unit should be at least 150mm
away from any inflammables.
y
If right and left walls are non-combustibles then
the unit should be at least 45mm from the walls.
y
Heatproof panels (insulating plate should be at least
3mm of metal or other non-combustible materials.
y
The top of the exhaust pipe should be at least
150mm from the ceiling.
y
There is a danger of a fire if the above terms are
not adhered.
Please install the unit in a boiler room away
from the effects of rain or wind.
y
Any rain or rain may cause improper combustion
causing exhaust fume poisoning.
Please do not install the unit in a location
where there is high humidity such as
bathroom and other closed spaces.
y
Due to lack of oxygen causing improper
combustion leading to CO poisoning.
y
Also, this may cause malfunction in a unit early.