Please install in a remote location where
there is no affects from snow or rain and
strong winds.
y
If icicles form from the evaporation due to the
exhaust gas during the winter months, they may
fall causing physical or property damage.
In the tunnel portion where the pipe goes
through the wall, it must be completely
airtight in order to prevent any exhaust gas
from re-entering inside.
y
If the exhaust gas enters inside, it may cause
exhaust gas poisoning.
The connection portion of the exhaust flue
must be completely airtight.
y
In case of leaks, exhaust gas leakage may cause
carbon monoxide poisoning.
Please install so that the intake side or the
exhaust side of the supply/exhaust pipes are
not inside of the wall.
y
If the intake / exhaust openings are inside of
the wall, there may be incomplete combustion
due to lack of oxygen causing Carbon Monoxide
poisoning.
Forced Draught Balanced
(FF) Flue Construction