2BC/D
1-5-48
Problem
Causes
Check procedures/corrective measures
(43)
The fixing web sole-
noid does not oper-
ate.
(44)
The cleaning lamp
does not turn on.
(45)
The exposure lamp
does not turn on.
(46)
The exposure lamp
does not turn off.
(47)
Fixing heater M or S
does not turn on
(C6000).
(48)
Fixing heater M or S
does not turn off.
(49)
Main charging is not
performed (C5100).
Broken fixing web solenoid
coil.
Poor contact in the fixing
web solenoid connector
terminals.
Defective engine PCB.
Poor contact in the clean-
ing lamp connector termi-
nals.
Defective cleaning lamp.
Defective engine PCB.
Poor contact in the expo-
sure lamp connector termi-
nals.
Defective inverter PCB.
Defective scanner drive
PCB.
Defective inverter PCB.
Defective scanner drive
PCB.
Broken wire in fixing
heater M or S.
Fixing unit thermostat trig-
gered.
Dirty sensor part of the
fixing unit thermistor.
Defective engine PCB.
Broken main charger wire.
Leaking main charger
housing.
Poor contact in the high
voltage transformer PCB
connector terminals.
Defective engine PCB.
Defective high voltage
transformer PCB.
Check for continuity across the coil. If none, replace the fixing
web solenoid.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Run maintenance item U033 and check if CN14-4 on the engine
PCB goes low. If not, replace the engine PCB.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Check for continuity. If none, replace the cleaning lamp.
If the cleaning lamp turns on when CN4-11 on the engine PCB is
held low, replace the engine PCB.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
If the exposure lamp turn on when CN1-5 and CN1-6 on the in-
verter PCB are held low, replace the inverter PCB.
If the exposure lamp turn on when CN3-1 and CN3-2 on the
scanner motor PCB are held low, replace the scanner drive
PCB.
If the exposure lamp does not turn off with CN1-5 and CN1-6 on
the inverter PCB high, replace the inverter PCB.
If CN3-1 and CN3-2 on the scanner motor PCB are always low,
replace the scanner drive PCB.
Check for continuity across each heater. If none, replace the
heater (see page 1-6-55).
Check for continuity across thermostat. If none, remove the
cause and replace the thermostat.
Check visually and clean the thermistor sensor parts.
If fixing heater M/S stays on while CN2-5 and CN2-6 on the en-
gine PCB go high, replace the engine PCB.
See page 1-5-33.
Summary of Contents for Ri 4530 Copystar
Page 1: ...SERVICE MANUAL Published in Feb 02 2BC70941 Revision 1 Ri 4530 5530 ...
Page 76: ...2BC D 1 1 4 13 This page is intentionally left blank ...
Page 100: ...1 4 35 2BC D 1 This page is intentionally left blank ...
Page 142: ...2BC D 1 This page is intentionally left blank ...
Page 173: ...2BC D 1 This page is intentionally left blank ...
Page 187: ...2BC D 1 1 5 42 This page is intentionally left blank ...
Page 374: ...2BC D 1 2 4 16 This page is intentionally left blank ...
Page 380: ...2BC D 1 2 4 22 This page is intentionally left blank ...