2BC/D-1
1-4-39
Maintenance
Description
item No.
U161
Setting the fixing control temperature
Description
Changes the fixing control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fixing problem on thick paper.
Method
Press the start key. The screen for adjustment is displayed.
Display
Description
Setting range
Initial setting
CONT TEMP
Control temperature during copying
170 to 200 (°C)
185
1ST TEMP
Primary stabilization fixing temperature
140 to 200 (°C)
165
2ND TEMP
Secondary stabilization fixing temperature
170 to 200 (°C)
185
TIME
Aging time after secondary stabilization
0 to 180 (s)
120
THICK ADJ
Compensation value for setting card
0 to 15 (°C)
10
stock/postcard through the bypass
Setting
1. Select the item to be set. The selecting item is displayed in reverse.
2. Change the setting using the cursor up/down keys.
The respective temperatures are to be set such that 2ND TEMP >
= 1ST TEMP.
3. Press the start key. The value is set.
Interrupt copy mode
While this maintenance item is being performed, copying from an original can be made in interrupt copy mode.
Completion
Press the stop/clear key at the screen for adjustment. The screen for selecting a maintenance item No. is
displayed.
U162
Stabilizing fixing forcibly
Description
Stops the stabilization fixing drive forcibly, regardless of fixing temperature.
Purpose
To forcibly stabilize the machine before the fixing section reaches stabilization temperature.
Method
1. Press the start key. The screen for executing is displayed.
2. Press the start key. The forced stabilization mode is entered, and stabilization operation stops regardless
of fixing temperature. The screen for selecting a maintenance item No. is displayed.
To exit the forced stabilization mode, turn the power off and on.
Completion
To exit this maintenance item without executing forced fixing stabilization, press the stop/clear key. The screen
for selecting a maintenance item No. is displayed.
U163
Resetting the fixing problem data
Description
Resets the detection of a service call code indicating a problem in the fixing section.
Purpose
To prevent accidents due to an abnormally high fixing temperature.
Method
1. Press the start key. The screen for executing is displayed.
2. Press EXECUTE on the touch panel.
3. Press the start key. The fixing problem data is initialized.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Summary of Contents for Ri 4530 Copystar
Page 1: ...SERVICE MANUAL Published in Feb 02 2BC70941 Revision 1 Ri 4530 5530 ...
Page 76: ...2BC D 1 1 4 13 This page is intentionally left blank ...
Page 100: ...1 4 35 2BC D 1 This page is intentionally left blank ...
Page 142: ...2BC D 1 This page is intentionally left blank ...
Page 173: ...2BC D 1 This page is intentionally left blank ...
Page 187: ...2BC D 1 1 5 42 This page is intentionally left blank ...
Page 374: ...2BC D 1 2 4 16 This page is intentionally left blank ...
Page 380: ...2BC D 1 2 4 22 This page is intentionally left blank ...