2BC/D
1-5-35
Causes
Check procedures/corrective measures
1. Dirty contact glass.
2. Dirty or flawed drum.
3. Deformed or worn cleaning blade.
4. Dirty scanner mirror.
(6) A black line appears
longitudinally.
Causes
1. Dirty contact glass.
2. Dirty or flawed drum.
3. Deformed or worn cleaning blade.
4. Dirty scanner mirror.
Clean the contact glass.
Clean the drum or, if it is flawed, replace it (see page 1-6-42).
Replace the cleaning blade (see page 1-6-52).
Clean the scanner mirror.
Causes
Check procedures/corrective measures
1. Dirty main charger wire.
2. Defective exposure lamp.
Causes
Check procedures/corrective measures
1. Flawed drum.
2. Dirty developing section.
3. Leaking main charger housing.
(7) A black line ap-
pears laterally.
Causes
1. Flawed drum.
2. Dirty developing section.
3. Leaking main charger housing.
(8) One side of the
copy image is
darker than the
other.
Causes
1. Dirty main charger wire.
2. Defective exposure lamp.
Replace the drum (see page 1-6-42).
Clean any part contaminated with toner or carrier in the developing
section.
Clean the main charger wire, grid and shield.
Clean the main charger wire or, if it is extremely dirty, replace it.
Check if the exposure lamp light is distributed evenly. If not, replace
the exposure lamp (see page 1-6-21).
Summary of Contents for Ri 4530 Copystar
Page 1: ...SERVICE MANUAL Published in Feb 02 2BC70941 Revision 1 Ri 4530 5530 ...
Page 76: ...2BC D 1 1 4 13 This page is intentionally left blank ...
Page 100: ...1 4 35 2BC D 1 This page is intentionally left blank ...
Page 142: ...2BC D 1 This page is intentionally left blank ...
Page 173: ...2BC D 1 This page is intentionally left blank ...
Page 187: ...2BC D 1 1 5 42 This page is intentionally left blank ...
Page 374: ...2BC D 1 2 4 16 This page is intentionally left blank ...
Page 380: ...2BC D 1 2 4 22 This page is intentionally left blank ...