2FT
1-4-26
U099
Checking the original size detection
Description
Checks the operation of the original size detection sensor and sets the sensing threshold value.
Purpose
To adjust the sensitiveness of the sensor and size judgement time if the original size detection sensor mal-
functions frequently due to incident light or the like.
Start
1. Press the start key. The screen for selecting an item is displayed.
2. Select an item using the up/down cursor keys.
3. Press the start key. The screen for executing each item is displayed.
Method to display the data for the sensor
1. Press the start key. The detection sensor transmission data is displayed.
Figure 1-4-5
2. To return to the screen for selecting an item, press the stop/clear key.
Setting
1. Select an item to be set using the up/down cursor keys.
Time from activation of the original detection switch (ODSW) to original size judgment
Method to set the detection threshold value
1. Adjust the preset value using the left/right cursor keys.
A larger value increases the sensor sensitivity, and a smaller value decreases it.
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Method to set the original size judgment time
1. Adjust the preset value using the left/right cursor keys.
A larger value increases the original size judgment time, and a smaller value decreases it.
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for maintenance item No. is dis-
played.
Maintenance
item No.
Description
Display
Description
DATA
Displaying detection sensor transmission data
B/W LEVEL
Setting detection sensor threshold value
Setting original size judgment time
: 123 123 123
: 123 123 123
: 255 255 255
Rear of machine
Center of machine
Front of machine
Display
Description
Setting range
Initial setting
LEVEL
Detection sensor threshold value
0 to 255
170
WAIT TIME
Original size judgment time*
0 to 100
30
A4R AREA
Threshold value in the main scan direction
for A4R detection
220 (mm)/
240 (mm)
240
ORG AREA
Original size detection position display (mm) 0 to 350
-
SIZE
Detected original size display
0 to 63
-
Summary of Contents for KM-2550
Page 1: ...SERVICE MANUAL Published in June 2005 842FT112 Version 3 0 KM 2550...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 123: ...2FT 1 1 4 56 This page is intentionally left blank...
Page 249: ...2FT 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC...
Page 267: ...2FT 2 3 20 Figure 2 3 10 Operation unit PCB silk screen diagram...
Page 282: ......