2FT
1-3-32
Job separator
Small pin
Large pin
Attach the job separator.
7. Insert the job separator from the MFP front
side and slide it to the left to install to the
ejection part.
8. Place the job separator closer to the ejection
side and then secure the front side (left
tapped hole) with the large pin and the rear
side with the small pin.
Figure 1-3-59
9. Loosen the screw that secures the drive unit
located at the rear side of the job separator
to make it ready for starting to drive and
then retighten the screw.
10. Connect the connector of the job separator
to YC5 on the engine circuit board.
11. Attach the cover that has been removed by
Procedure 6 to its original position using the
two screws.
Figure 1-3-60
Screw
YC5
Drive unit
Connector