
2FT
1-4-8
U019
Displaying the ROM version
Description
Displays the part number of the ROM fitted to each PCB.
Purpose
To check the part number or to decide if the ROM version is new from the last digit of the number.
Method
1. Press the start key. The part number indicating the ROM version are displayed.
2. Change the screen using the up/down cursor keys.
*: Optional.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U020
Initializing all data
Description
Initializes all the backup RAM on the main PCB to return to the original settings.
Purpose
Run as needed.
Method
1. Press the start key. The screen for executing is displayed.
2. Select the EXECUTE using the up/down cursor keys. It is displayed in reverse.
3. Press the start key. All data in the backup RAM is initialized, and the original settings for Japan specifi-
cations are set.
When initialization is complete, the machine automatically returns to the same status as when the main
switch is turned on.
Completion
To exit this maintenance item without executing initialization, press the stop/clear key. The screen for selecting
a maintenance item No. is displayed.
U021
Initializing memories
Description
Initializes the setting data other than that for adjustments due to variations between respective machines, i.e.,
settings for counters, service call history and mode settings. As a result, initializes the backup RAM according
to the specifications depending on the destination selected in U252.
Purpose
Used to return the machine settings to the factory settings.
Method
1. Press the start key. The screen for executing is displayed.
2. Select the EXECUTE using the up/down cursor keys. It is displayed in reverse.
3. Press the start key. All data other than that for adjustments due to variations between machines is initial-
ized based on the destination setting.
Completion
To exit this maintenance item without executing initialization, press the stop/clear key. The screen for selecting
a maintenance item No. is displayed.
Maintenance
item No.
Description
Display
Description
MAIN
Main ROM IC
ENGINE
Engine ROM IC
LANG(St)
Standard language ROM IC
LANG(Op)
Optional language ROM IC
MAIN BOOT
Boot of main ROM IC
PRINTER
Printer board ROM IC
NWS
Network scanner* ROM IC
DP
DP* ROM IC
FINISHER
Finisher* ROM IC
CASS2
First paper feeder ROM IC
CASS3
Second paper feeder* ROM IC
CASS4
Third paper feeder* ROM IC
Summary of Contents for KM-2550
Page 1: ...SERVICE MANUAL Published in June 2005 842FT112 Version 3 0 KM 2550...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 123: ...2FT 1 1 4 56 This page is intentionally left blank...
Page 249: ...2FT 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC...
Page 267: ...2FT 2 3 20 Figure 2 3 10 Operation unit PCB silk screen diagram...
Page 282: ......