2FT-1
1-5-24
C6420
Fixing fuse cut problem
When you try to cut the fixing fuse, the
fixing is not cut even after 3 s elapse.
Poor contact in the
connector termi-
nals.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
Fixing unit connec-
tor inserted incor-
rectly.
Reinsert the fixing unit connector if neces-
sary.
C7400
Developing unit connector insertion
problem
Absence of the developing unit is
detected.
Developing unit
connector inserted
incorrectly.
Reinsert the developing unit connector if
necessary.
Defective develop-
ing unit connector.
Replace the developing unit.
C7410
Drum unit connector insertion prob-
lem
Absence of the drum unit is detected.
Drum unit connec-
tor inserted incor-
rectly.
Reinsert the drum unit connector if neces-
sary.
Defective drum unit
connector.
Replace the drum unit.
C7800
Broken external temperature ther-
mistor
The input voltage is 0.5 V or less.
Poor contact in the
humidity sensor
connector termi-
nals.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
Defective humidity
sensor.
Replace the drawer PCB and check for cor-
rect operation.
C7810
Short-circuited external temperature
thermistor
The input voltage is 4.5 V or more.
Poor contact in the
humidity sensor
connector termi-
nals.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
Defective humidity
sensor.
Replace the drawer PCB and check for cor-
rect operation.
C8170
Finisher* front side registration motor
problem
If the front side registration home posi-
tion sensor is on in initialization, the sen-
sor does not turn off within 570 ms of
starting initialization.
If the front side registration home posi-
tion sensor is off in initialization, the sen-
sor does not turn on within 3180 ms of
starting initialization.
The front side reg-
istration motor con-
nector makes poor
contact.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
The front side reg-
istration motor mal-
functions.
Replace the front side registration motor and
check for correct operation.
The front side reg-
istration home
position sensor
connector makes
poor contact.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
The front side reg-
istration home
position sensor
malfunctions.
Replace the front side registration home
position sensor and check for correct opera-
tion.
Defective finisher
main PCB.
Replace the finisher main PCB and check
for correct operation.
*: Optional.
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Summary of Contents for KM-2550
Page 1: ...SERVICE MANUAL Published in June 2005 842FT112 Version 3 0 KM 2550...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 123: ...2FT 1 1 4 56 This page is intentionally left blank...
Page 249: ...2FT 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC...
Page 267: ...2FT 2 3 20 Figure 2 3 10 Operation unit PCB silk screen diagram...
Page 282: ......