2H0/2HZ-1
1-4-19
Measures against the service codes detecting fuser problems
If one of the following service codes is detected, take actions to clear the cause of the trouble and perform maintenance
item U163 to reset the service code.
(2) Self diagnostic codes
Code
Contents
C6000
Fuser heater break
C6020
Abnormally high fuser thermistor center temperature
C6050
Abnormally low fuser thermistor center temperature
C6120
Abnormally high fuser thermistor edge temperature
C6150
Abnormally low fuser thermistor edge temperature
C6400
Zero-cross signal error
C6420
Fuser unit fuse cut problem
Code
Contents
Remarks
Causes
Check procedures/corrective measures
C0060
Main PWB type mismatch error
Defective PWB.
Run maintenance item U935 to contact the
Service Administrative Division.
C0120
Drum EEPROM error
Reading from or writing to EEPROM
cannot be performed.
Poor contact in the
connector termi-
nals.
Check the connection of connector on the
engine PWB and the continuity across the
connector terminals. Repair or replace if
necessary.
Defective drum
unit.
Replace the drum unit.
C0130
Backup memory (EEPROM) device
problem (Main PWB)
Reading from or writing to EEPROM
cannot be performed.
Defective main
PWB.
Replace the main PWB and check for cor-
rect operation.
Device damage of
EEPROM.
Contact the Service Administrative Division.
C0150
Backup memory (EEPROM) device
problem (Engine PWB)
Reading from or writing to EEPROM
cannot be performed.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation.
Device damage of
EEPROM.
Contact the Service Administrative Division.
C0160
Backup memory (EEPROM) data
problem (Engine PWB)
Reading data from EEPROM is abnor-
mal.
Read and write data does not match 5
times continuously.
Problem with the
backup memory
data.
Run maintenance item U022 to initialize the
backup memory data.
Defective engine
PWB.
If the C0160 is displayed after initializing the
backup memory, replace the engine PWB
and check for correct operation.
C0180
Machine number mismatch error
Machine number of main PWB and
engine PWB does not match.
Data damage of
EEPROM.
Contact the Service Administrative Division.
C0320
Power CPU communication problem
The engine PWB and the power CPU
are unable to communicate with each
other.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation.
Summary of Contents for 1102H03NL0
Page 1: ...SERVICE MANUAL Published in April 2008 842H0112 2H0SM062 Rev 2 KM 2560 KM 3060...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 14: ...2H0 2HZ This page is intentionally left blank...
Page 20: ...2H0 2HZ 1 1 6 This page is intentionally left blank...
Page 36: ...2H0 2HZ 2 1 2 16 This page is intentionally left blank...
Page 262: ...2H0 2HZ 2 1 20 This page is intentionally left blank...
Page 323: ...INSTALLATION GUIDE FOR PAPER FEEDER...
Page 324: ...CAUTION 2007 6 303K656810 PRECAUCION VORSICHT ATTENZIONE ATTENTION...
Page 347: ...INSTALLATION GUIDE FOR BUILT IN FINISHER...
Page 359: ...INSTALLATION GUIDE FOR JOB SEPARATOR...
Page 369: ...INSTALLATION GUIDE FOR FAX System M...
Page 385: ...INSTALLATION GUIDE FOR Data Security Kit C...
Page 388: ...INSTALLATION GUIDE FOR UG 30...
Page 391: ......
Page 392: ......