Cable Connection
18
the end to the grounding screw and connect the other end to the earth firmly.
Figure 21 Grounding
Note:
Cross-sectional area of the chassis grounding cable>2.5mm
2
;Grounding resistance<5
.
4.6 Power Terminal Block
There is a power terminal block on the top panel of the switch. You need to connect the
power cable to the terminal block to provide power for the switch. The switch supports both
single power supply and dual power supply for redundancy with a 5-pin 5.08mm-spacing
plug-in terminal block. When the dual power supply is used and one power input is faulty, the
switch can continue operating properly, thereby improving network reliability.
Note:
Grounding resistance<5
.
Use copper conductors only, temperature rating 75
℃
only.
5-Pin 5.08mm-Spacing Plug-in Terminal Block
The following figure lists the pin definitions of the 5-pin 5.08mm-spacing plug-in terminal
block.
Figure 22 5-Pin 5.08mm-Spacing Plug-in Terminal Block (Socket)
The following figure lists the pin definitions of the 5-pin 5.08mm-spacing plug-in terminal
block.