Make cooling circuit.
For this, connect the system cooler and compensator using the coolant
hoses.
Photo17: Coolant hose
1.
Cooler connection – plug nipple DN 7.2
2.
Compensator connection – Hasco coupling Z80/9/90
3.
Coolant hose – length approx. 3 metres
4.
Fill cooler according to instructions with coolant and bleed pump.
5.
Connect generator and cooler with 230 V mains.
6.
Switch on cooler
7.
Switch on generator
(The fault control lamp lights immediately after switching on. It goes out
after a few seconds. Afterwards the equipment is ready for use.)
8.
Set the power regulator to the smallest value.
9.
Press the remote control switch or test button.
10.
Adjust the power regulator as necessary to the required power for the
part to be heated.
11.
The maximum coolant pressure must not exceed 4 bar. The tempera-
ture of the coolant should not be significantly less than room tempera-
ture (condensation forming).
12.
Setting up work must only be carried out when the generator is
switched off.