71
Chapter 12
212121212
Troubleshooting
12
12.1 Error messages
If the ADU should fail an error message will be sent to the Error log. See User
Manual chapter 4 “Operation” and 2.6 “The Handset”.
The error message does not pinpoint the exact location of the unit, which is
causing the fault – but it gives an idea of where to start troubleshooting. The
error message can be hardware or software related.
If an error message is received - start the troubleshooting by restarting the
system.
If other error messages than those shown in the table are received – contact
supplier or Thrane & Thrane for Support.
Error message
Possible reason
Action
FEU Status
Heat alarm
System error
Restart the system
Temperature inside the
radome exceeds 90
°
C.
Switch off system
and/or open service
hatch to ventilate the
radome.
HPA cooler fan failure
HPA failure
Replace HPA module
FEU Status
Burst alarm
FEU Status
Power alarm
System error
Restart the system
HPA fault
Replace HPA module
Summary of Contents for TracPhone F55
Page 22: ...Table of Contents x...
Page 28: ...Chapter 2 GMDSS Installations 6 Power Supply...
Page 40: ...Chapter 3 Placing the Antenna 18 Antenna Mast Design...
Page 48: ...Chapter 5 Installing the BDU 26 Grounding the BDU...
Page 54: ...Chapter 6 F77 Distress Cradle 32 Assembly Alternative...
Page 58: ...Chapter 7 F55 Passive Cradle 36 Passive Cradle Assembly...
Page 64: ...Chapter 8 Connecting Power 42 Power supply specification...
Page 84: ...Chapter 10 Hardware Interfaces 62 Discrete I O interface...
Page 116: ...Appendix C F55 77 BDU Technical Specifications 94 Measuring the Ship Source Impedance...
Page 120: ...Appendix D Distress Cradle Technical Specifications 98 Outline Dimensions...
Page 123: ...Chapter E Passive Cradle Technical Specifications Outline Dimensions 101 EEE...
Page 124: ...Chapter E Passive Cradle Technical Specifications 102 Outline Dimensions...