Appendix G: Grounding and RF protection
Separate Ground Cable
123
GGG
G.9.3 Isolation of ADU from the mounting base
In cases where the ADU is to be isolated from the mounting base, shoulder
bushes and washers (accessories) must be used as illustrated below. Please
note that the isolation has to be implemented on all four mounting bolts
(including the bolt securing the ground cable).
M10 Isolation Washer
Mounting Base
M10 Screw Insulator
Grounding/Mounting Stud on ADU
Plain Washer (stainless steel)
Spring Washer (stainless steel)
ADU
M10 Mounting Bolt
(stainless steel)
tighten to 25 +/- 5 Nm